DL76 data logger

The DL76 is a battery-powered data logger (estimated battery life is 3-5 years, depending on usage) that can be used with any Seametrics flow meter. Pulses are stored in a choice of 6 sampling intervals from 15 seconds to 1450 seconds that give a capacity ranging from 11 days to 3 years. Indicator lights on the unit flash to indicate when it is functioning and when the battery is low. 

The DL76 is available either as a wall-mount unit here, or pre-mounted on an insertion meter.
Housings are rugged cast aluminum, gasketed for environmental protection.
When a DL76 logger is placed into operation, it is easily set up using a laptop computer. Data is also retrieved from the DL76 by means of a laptop and can be analyzed on the laptop or easily loaded on a desktop computer for analysis.
The DL76 is available with a Tamper-Evident Kit (“-32” option). A wire with a seal runs through the screws, so that the unit can’t be opened without breaking the seal.
FlowInspector version 2 software (order separately here as part #102513) is required for the downloading, storing, viewing, graphing, charting and printing of data in several formats. FlowInspector requires a PC with Windows 98, NT, 2000, XP, Vista or Windows 7; CD-Rom drive; 800 x 600 screen resolution; serial port or USB/serial adapter; and a Seametrics DC3 data cable. FlowInspector can be used with an unlimited number of data loggers.
  • Mount: Wall mount
  • Power: Battery powered
  • Input: Maximum input frequency 500 Hz
  • Includes: Battery
  • Not Included: Software ordered separately
  • Weight: 3 lbs
  • Easy to set-up, easy to use
  • Weeks/months/years of data storage
  • User-selected sampling interval
  • Data retrieval with laptop computer
  • Single data retrieval device serves multiple data loggers
  • Water usage monitoring, reporting, and management
  • Custody transfer regulation
  • Peak demand monitoring
  • Power : Size C 3.6 Vdc lithium battery (included)
  • Battery Life : Estimated life is 3-5 years depending on usage.
  • Temperature : 0˚ to 130˚ F (-18˚ to 54˚C)
  • Rate Units 
    • Volume : ml, liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon
    • Time : Seconds, minutes, hours, days
  • Total Units : Liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon, acre-foot, acre-inch, mega liter,  thousand -gallon
  • Data Storage Capacity 
  • Capacity at sampling Interval :
    • 11 days   at  15 seconds
    • 22 days   at  30 seconds
    • 44 days   at  60 seconds
    • 6 months   at  240 seconds
    • 1 year   at  480 seconds
    • 3 years   at  1450 seconds
  • Input Frequency : 500 Hz Maximum 