The FLUXUS
F401 is the ideal flow meter for long-term measurement campaigns in the
field. Depending on the programmed measurement interval the FLUXUS F401
can operate autonomously for several months. This makes it suitable for
leak detection campaigns and hydraulic studies, where regular
measurements are needed over a longer period of time.
The clamp-on ultrasonic system has been designed specially to meet the needs of the water and wastewater industries. The FLUXUS F401 is installed without process interruption and the installation can be completed within a few minutes.
Thereafter, it delivers accurate and highly repeatable measurements that are not affected by drift. Due to its excellent low flow capability (down to 0.01 m/s), the FLUXUS F401 is ideally suited for monitoring drinking water networks, in which low flow velocities are common.
The strong signal output and the noise suppression technology make it possible to use the FLUXUS F401 on very large pipes and challenging materials: Old and rusty steel, badly manufactured GRP or even armored concrete pipes (independent of lining and build-up inside the pipe) are not a metering challenge to the FLUXUS F401.
All parts of the FLUXUS F401 have been designed to ensure utmost robustness for regular heavy duty use in rough conditions. The metal sheathing of the transducer cable ends protects them against strong bending or cuts and ensures tangle-free operation.
The six-meter cable length of the IP68 transducers allows for the installation of the transducers even in deep manholes, whereby the transmitter can be placed in the upper part of the manhole. The transmitter is housed in a robust case and has IP67 protection.
All this makes the FLUXUS F401 the ideal companion for the daily work of water suppliers, hydrologists, and engineering offices.
The clamp-on ultrasonic system has been designed specially to meet the needs of the water and wastewater industries. The FLUXUS F401 is installed without process interruption and the installation can be completed within a few minutes.
Thereafter, it delivers accurate and highly repeatable measurements that are not affected by drift. Due to its excellent low flow capability (down to 0.01 m/s), the FLUXUS F401 is ideally suited for monitoring drinking water networks, in which low flow velocities are common.
The strong signal output and the noise suppression technology make it possible to use the FLUXUS F401 on very large pipes and challenging materials: Old and rusty steel, badly manufactured GRP or even armored concrete pipes (independent of lining and build-up inside the pipe) are not a metering challenge to the FLUXUS F401.
All parts of the FLUXUS F401 have been designed to ensure utmost robustness for regular heavy duty use in rough conditions. The metal sheathing of the transducer cable ends protects them against strong bending or cuts and ensures tangle-free operation.
The six-meter cable length of the IP68 transducers allows for the installation of the transducers even in deep manholes, whereby the transmitter can be placed in the upper part of the manhole. The transmitter is housed in a robust case and has IP67 protection.
All this makes the FLUXUS F401 the ideal companion for the daily work of water suppliers, hydrologists, and engineering offices.
Applications
- Temporary measurements in the water and wastewater industry
- Leakage detection
- Water loss balancing
- Accuracy verification of permanently installed flowmeters
- Monitoring of pumping tests
Specification
Measurement accuracy | ±2.0 % of reading ±0,01 m/s |
Repeatability | 0.25 % of reading ±0,01 m/s |
Flow velocity range | 0,01 … 25 m/s |
Pipe diameter range | 40 mm … 3000 mm |
Outputs | 1x Current, 1x Binary |
Communication Interface | RS232 / USB (with adapter) |
Fluid | water with <6 by="" content="" gaseous="" or="" solid="" span="" volume="">6> |
Power Supply | 100…230 V/50…60 Hz (power supply unit |
12 V DC (socket at the transmitter) | |
integrated battery | |
Physical Quantities | volumetric flow rate, mass flow rate, flow velocity |
Totalizer | volume, mass |
Operating Temperature | Transmitter: -10 °C … 50 °C |
Transducer: -40 °C … 100 °C | |
Degree of protection | Transmitter: IP67 (when closed), IP65 (when open) |
Transducer: IP68 |