Hazardous Locations Meet High Programmability. Made for highly configurable measurement in linear and non-linear tanks and channels, the LPU-2428 can internally calculate distance, level, flow, and volume. Intelligent and highly configurable. The LPU-2428 can calculate distance, level, flow, and volume in linear and non-linear tanks. With Class 1 Division 1 ratings, the loop powered LPU-2428 is built to handle the most hazardous locations. Add the ability to internally calculate volume or open channel flow data, and you have a unique and powerful ultrasonic sensor.
Programmable Intelligence
The LPU-2428 was made with intelligent software for highly configurable measurement. The sensor can calculate distance, level, flow, and volume. In addition, the sensor features a 32-point linearization table for non-linear tanks and channels.
Class 1, Div. 1
This loop powered sensor is suitable for use in hazardous areas rated CSA Class 1, Div. 1.
Maintenance-Free
With a tough, IP65-rated housing, its hazardous rating, and non-contact measurement, the LPU-2428 takes care of itself.
Features
- Loop powered 4-20 mA output
- Class 1 Division 1, Intrinsically Safe rating
- Built-in calculations of current volume, flow, and flow totals
Application
- CI, D 1 Hazardous Locations
- Open-channel Flow
- Non-linear Tanks
- Dam Tail-water Levels
- Irrigation Channel Level or Flow
Another Article: |
Specification
Performance | |
Operating Range | 1 to 25 ft. for liquids |
1 to 10 ft. for solids | |
Accuracy | ±0.25% of detected range |
Resolution | 0.1 in. |
Response Time | From 0.6 to 3 sec. (programmable) |
Electrical | |
Supply Voltage | 12-28 VDC |
(loop current 4-20mA) | |
Approvals | |
Certifications | CSA C/US |
Class 1, Div. 1, Groups C & D | |
Class 1, Zone 0, AEx ia IIB T3 | |
Class 1, Div. 2, Groups C & D | |
Class 1, Zone 2, AEx nA IIB | |
T6 | |
Connectivity | |
Output | 4-20mA |
Cable | 2-conductor shielded |
Internet Connectivity | with RST-5003 |
Programming | |
Method | RST-4101 Programming Module |
Calculations | Distance, Level, Volume, Flow |
Tank/Channel Adjustments | 32-point linearization table |
Physical | |
Housing | PVDF transducer housing & threads |
PET upper housing | |
Mounting | 2 in. NPT |
Environmental | |
Operating Temperature | -40 to 140° F |
Temperature Compensation | Internal |
Protection Rating | IP65 |