BGK Kobold Variable Area Flowmeter



Function

The fluid flows from bottom to top through the meter tube of the flowmeter. The float is lifted until an annular gap between the measuring cone and the float is produced which corresponds to the flow. The forces acting on the float are in equilibrium.

The height of the float resulting from the flow rate is transmitted by the permanent magnet in the float through the magnetic tracking system in a rotation to the pointer axis of the analog indicator unit.

The variable-area flowmeter consists of a stainless steel device with an integrated conical stainless steel measuring tube and a vertically movable float.

Measuring range:
0.1 - 1 ... 20 - 200 l/h water
5.0 - 50  ... 600 - 6000 Nl/h air
Connection: flange DN10 - 25 or ANSI ½", ¾", 1"
Material: stainless steel
pmax: 40 bar (higher on request)
Temperature range: -40 ... +130°C
Contact: -25 ... +100°C, analogue output: -40 ... +100°C
Accuracy: ±3 % qG = 50 %
Option: contacts, analogue output
Protection: IP65 (EN60529)
Explosion protection: BVS 03 ATEX H/B 113

Features

Application

The KDS meter is suitable for flow measurement of liquid or gaseous products in pipes.
It shows the current flow rate in volume or mass per unit in time.

Areas of Application

  • Flow measurement of liquids and gases
  • Can be used in the chemical industry or in medical or laboratory engineering
  • Robust mechanical system with a low rate of wear

The devices are available with additional electrical equipment for process monitoring and control

  • A variety of sealing materials
  • High pressure application (option)
  • Analogue output (option)

  Another Article:

Specifications

Technical Data

Materials

  • Indicator housing: polyamide, cover Ultramid
  • Measuring cone, float, armature: stainless steel 1.4404/1.4571
    other materials on request
  • Process connection: flange see order details
  • Nominal pressure: PN 40/300 lbs
  • Accuracy liquid/gas: ±3 % qG 50 acc. VDE/VDI 3513
  • Process temperature:
    Without limit contact/ electronic: -40°C...+130°C
    With limit contact: NJ1,5-6,5N -25…+100°C; NJ2-11SN -40…+100°C
    With analogue output: -40…+100°C (BGK-..E)
  • Ambient temperature: -25°C...+70°C
  • Weight: 2.4 kg
  • Protection: IP 65 (EN60529)
  • Display: %-scale
    measuring range scale

Certificate and Approval
Explosion protection: BVS 03 ATEX H/B 113

Download Datasheet: BGK Kobold Variable Area Flowmeter

Reference : kobold.com