The TP19 resistance thermometers with/without transmitter are powerful, rugged devices for process measurements, the food, pharmaceutical and chemical industry, etc., completely made of stainless steel in a sealed design for hygienic applications.
The standard version of the temperature sensor is designed according to Accuracy Class A. Accuracy classes B 1/2, 1/3, 1/10 DIN are optionally available. The measuring inserts are single or double PT 100s, which can be exchanged.
The utilisation of the measuring inserts must be adapted to the requirements with regard to temperature, length, flexibility, vibration resistance and measuring accuracy. Special devices are available for control processes, e.g. tapered sensor tip for particularly short half-value times.
The design according to IP 67 with exchangeable test insert provides access to the measuring point at any time and offers a reliable guarantee for tightness and long operating times, even under extreme operating conditions, as well as saving resources. Programmable 4-20 mA, HART or Profibus PA transmitters can be installed for transmission of the measuring values. The QUICKTEMP series is particularly recommended for measuring points that require calibration.
Features:
- "fr" housing in ip 67
- single or double pt100
- optionally with measuring transmitter
- connection "varivent" flange, d = 25 or 68 mm
- fully sealed
- short addressing times and tapered sensor tip
- optional as quicktemp versions for measuring points required for quality assurance
Specification:
Design configuration | |||
Type | Field housing (Cr Ni St) | ||
Temperature sensor | PT 100 according to EN 60751, exchangeable test insert (standard) | ||
Insertion tube 1.4571 | |||
Test insert, electrical | 1 x PT 100 in a 2-, 3- or 4-wire circuit, standard: 1 x 3-wire circuit, Class A, | ||
2 x PT 100 in 2- or 3-wire circuit | |||
Electrical connection | M 16x1.5 cable connection, MS-nickel-plated, | ||
Optional: | M12 x 1 round plug, 4-pin | ||
Accuracy | - Standard: Tolerance Class A according to EN 60751, | ||
- Optional: Tolerance categories B 1/10, 1/5, 1/3, 1/2 | |||
Response time | T50 (measured in water): 6 s (design-dependent, d = 6 mm), | ||
< 6 s with tapered sensor tip, on request) | |||
Temperature of measuring material | tmax at the sensor = -20... +200°C | ||
Casing material | Stainless steel 1.4301 (standard field housing) | ||
Sensor material | Stainless steel 1.4571, optional 316L = 1.4435 or 1.4404, | ||
Optional: High surface quality | |||
Sensor diameter | Standard: Continuously smooth, d = 6 mm, | ||
Optional: | Tapered sensor tip d = 4 mm | (exchangeable test insert) | |
Tapered sensor tip d = 3 mm or 2 mm (test insert not exchangeable) | |||
Sensor length | Standard EL: 35 mm, VARIVENT d = 68 mm, | ||
Deviating length on request | |||
Collared tube | Standard: Neck pipe length = 50 mm, d = 12 mm | ||
for extending the distance, depending on the operating temperature, | |||
optionally in other lengths | |||
Type of protection | EN 60529, IP 67 with cable connection, optionally with cable output | ||
Permitted pressure | DN = 10 bar, depending on design and temperature | ||
CE conformity | EMC guidelines are met, CE symbol | ||
Process connections | |||
-- VARIVENT flange d = 68 mm, DN 40/50 for pipe DN 40 – DN 125 | |||
-- Optional: - VARIVENT DN 25, d = 50 mm | |||
- VARIVENT DN 10/15, d = 31 mm | Material No. 1.4404, optional 1.4435 | ||
Accessories | |||
Parts for assembly | Accessories for VARIVENT installation systems on request | ||
Options | |||
Electrical connection | - Ceramic connection base | ||
- Flexible connection wires | |||
- Sheathed cable version (vibration-resistant version) | |||
- Transmitter TE 42, programmable, 4...20 mA, 2-wire switch (standard) | |||
- Transmitter TE 41, programmable, galvanically separated | |||
- Transmitter TE 52, HART | |||
- Transmitter TE 82, Profibus PA | |||
- Configuration set including adapter and software for TE41 / TE42 | |||
Process connections | - Tapered sensor tip D = 3 mm or 4 mm | ||
- Exchangeable test insert, d = 3 mm | |||
- Neck pipe L = 75 mm, d = 12 mm (please specify other length) | |||
- VARIVENT flange DN 25, 316L, fully welded | |||
Calibration | Factory calibration, calibration certificate (3-point / 5-point) with DKD standard | ||
Certificates | Material certificate according to EN 10204, EHEDG, FDA |
Download Data Sheet:Flange Resistance Thermometer TP 19
Ref: Hengesbach.com
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :