Sonic GF-2500 Ultrasonic Gas and Steam Flow Meter

 

The **Sonic GF-2500 Ultrasonic Gas and Steam Flow Meter** represents a significant renewal of the highly successful 30-year supply record of GF series gas flowmeters. This advanced device is equipped with an **ultrasonic thermometer**, a **widescreen display**, and a **multi-level output interface**. The GF-2500 is engineered to maximize performance in controlling and monitoring various gas flows, ultimately contributing to energy savings and cost reduction in industrial applications.

Features :

  • Wide-screen LCD and various display functions
  • High noise tolerance design
  • No pressure loss
  • Various output ports (analog x2, digital x1, contact x4)
  • Automatic pressure and temperature correction
  • Easy replacement with the compatibility of existing sensors
  • Wider measurement range

Specifications :

Pipe :

  • Fluid Condition: Gas and Steam
  • Applicable Pipe Diameter: Nominal diameter 50mm ∼ 5000mm (*1)
  • Spool Piece :
    • Pipe Diameter: 50mm∼500mm (*2)
    • Flange: JIS10K standard (*3)
    • Material: SGP, STPG, SUS316, SPTY (*4)
  • Socket: Standard Type
    • Screw Type
    • Flange Type (Screw type with sensor)
    • Flange Type (Large sensor type)

Sensor Probe :

  • Sensor Probe :
    • Gas :
      Standard (Screw type) Large (Flange Type)
      Nominal Diameter 50mm ∼ 10000mm (*5) 1000mm ∼ (*5)
      Temperature -30ºC ∼ 180ºC -30ºC ∼ 180ºC
      Pressure -0.05Pa ∼ 1MPa (0.5 ∼ 10kgf/cm³) -0.05Pa ∼ 1MPa (0.5 ∼ 10kgf/cm³)

    • Steam: Standard (Flange type) 1MPa (10kgf/cm³) type
    • Custom (*6)
  • Seal :
    • Probe fittings: Combine with gas seal unit
    • Gas seal unit: Standard, steam, large, custom
    • Gas Seal Adaptor: Instead of a gas seal unit (not used)
  • Installation Requirement :
    • Upstream side: 15D
    • Downstream side: 5D or more (D is inner diameter)
  • Cable: Distance from sensor probe to converter, 6m or 10m (standard)

Converter :

  • General :
    • Measuring method: Ultrasonic transit time flow meter
    • Chordal path: 1 path or 2 path (option)
    • Traverse: Z or V
    • Measurement compensation range: Temperature ±25ºC, Pressure ±30%
    • Accuracy: ±1.0% FS (flow velocity 5 ∼ 60m/s)
    • Reproducibility: 0.2%
    • Flow velocity resolution: Less than 0.5mm/s
    • Averaging: Default 10 sec (0.5∼180 sec variable)
    • Ultrasonic Thermometer: Measures temperature (in case of air) by ultrasonic transit time
    • Ambient Temperature: -10 ∼ +50ºC
  • Power Supply :
    • Power Supply: AC100V±10%, 50/60Hz, AC115V, 220V (option)
    • Surge Protection: Built-in surge absorber
    • Power Dissipation: Max. 25W




  • Output :

    Output Type Details
    Analog output 1 Range: DC4 ∼ 20mA
    Over range: DC0 ∼ 24mA
    Load resistance: Less than 1000Ω
    Analog output 2 Reverse flow, temperature, pressure
    Range: DC4 ∼ 20mA, isolated
    Over range: DC0 ∼ 24mA
    Load resistance: Less than 1000Ω
    Pulse output 1 Integrated pulse
    Open collector standard: 0V, 0.2A
    Pulse width: 1.6ms or 50ms
    Pulse output 2 Integrated pulse, alarm, normal and reverse flow, upper and lower limb
    Open collector standard: 30V, 0.2A
    Pulse output 3 Alarm, normal and reverse flow, upper and lower limit
    Open collector standard: 30V, 0.2A
    Pulse output 4 Alarm, normal and reverse flow, upper and lower limit
    Open collector standard: 30V, 0.2A
    Power supply for pressure and temperature DC24V +/-0.5V 0.2A
    Digital output RS422 x 1
    Input Temperature: DC4 ∼ 20mA
    Pressure: DC4 ∼ 20mA
    Display LCD: 128 x 240 dots LED backlight
    Character: Alphanumeric, mathematical symbols (e.g., +, -, Σ)
    Display content: Measurement display, Instantaneous flow rate (analog 1, 2), Input temperature, pressure, ultrasonic temperature meter. Can display 4 contents in all.

    Baca Juga :

Berbagi:  

Komentar

Articles