The iMAG-Series is the most economical flanged electromagnetic flowmeter on the market. With electrodes designed to discourage fouling, it is available in 3” to 12” pipe in municipal or industrial water, waste and reclaimed water, pump stations, and packaged plant applications. Minimal straight pipe requirements allow iMAG-Series meters to be used in piping configurations where there is little space between the meter and an elbow.

Seametrics iMAG 4700 Series Electromagnetic Flow Meter

Features

  • Easy setup
  • Minimal straight pipe
  • Mounted or remote rate & total
  • Tamper-evident seal
  • Certified to NSF/ANSI standard 61
  • IP68 rated
  • No moving parts

Application

  • Water & Wastewater Treatment
  • Municipal
  • Pump skids
  • Pump stations
  • Packaged plants
  • Filtration systems
  • Reclaimed water
  • Hydraulic fracturing
     Baca Juga :

Specification iMAG Water Flow Meter

Pipe Sizes3”, 4”, 6”, 8”, 10”, 12”
Flanges150 lb. ANSI Pattern
PressurePressure 150 psi (10.3 bar) line pressure
TemperatureOperating10˚ to 140˚ F (-12˚ to 60˚ C)
Storage-40˚ to 158˚ F (-40˚ to 70˚ C)
Accuracy±0.75% of reading on iMAG 4700p and 4700r (±1.0% iMAG 4700), ±0.025% of full-scale flow from low flow
cutoff to maxi. flow rate of 10 m/sec
Low Flow Cutoff0.5% of maximum flow rate
MaterialBody (3” only)Ductile cast iron, powder-coated
Body (4”-12”)Welded steel, epoxy-coated
Liner (3” only)Noryl®
Liner (4”-12”)Santoprene flange/Polypropylene liner body
Electronics HousingPowder-coated diecast aluminum
Electrodes316 stainless steel
O-ring (3” only)EPDM
DisplayType128x64 dot-matrix LCD
Digits5 Digit Rate8 Digit Total

Units

Please Note:
All iMAG meters are factory
set for gallons per minute
(GPM) rate and gallons
total. If other units are
required, they can be set in
the field

Rate Volume UnitsRate Time UnitsTotal Volume Units
Gallons
Liters
Barrels(42 gal)
Cubic Feet
Cubic Meters
Million Gallons²
Mega Liters²
Imperial Gallons
Million Imperial
Gallons²
Second
Minute
Hour
Day
Gallons
Liters
Barrels (42 gal)
Cubic Meters
Cubic Feet
Second Foot Day
Million Cubic Feet
Acre Feet
Acre Inches
Imperial Gallons
Fluid Ounces
Bidirectional¹Forward Total, Reverse Total, Net Total, Batch Forward Total, Batch Reverse Total (Batch totals can be reset)
PowerDC Power9-36 Vdc @ 250 mA max, 30 mA average
Battery Backup
(Not for use as primary power)
DC powered units: Two lithium 3.6V ‘D’ batteries, replaceable.
AC powered units: One 9V alkaline battery, replaceable.
AC Power (iMAG 4700r
and 4700p only)
85-264Vac, 50/60Hz, 0.12A
Battery (iMAG 4700 onlyOne lithium 7.2V ‘D’ size battery pack, replaceable.
Scaled Pulse
Output
SignalCurrent sinking pulse, isolated, 36 Vdc at 10 mA max
Pulse RatesUser-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150
pulses/sec max.
Options4-20mA Current LoopIsolated, passive, 24Vdc, 650 Ω maximum current loop
HART/4-20mAHART protocol over 4-20mA line
High Speed Digital
Output (iMAG 4700 &
4700p only)
Isolated, open collector, 24 Vdc
Serial CommunicationsIsolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus® RTU protocol (factory
selectable)
CablePower/Output Cable20ft (6m) standard length polyurethane jacketed cable—for power and outputs (lengths up to 200’ available).
Remote Display Cable
(iMAG 4700r)
20ft (6m) standard length polyurethane jacketed cable—for connection between meter and remote display (lengths up to 200’ available).
Conductivity>20 microSiemens/cm
Empty Pipe DetectionHardware/software, conductivity-based
Regulatory(EN 61326), 4”-12” certified to NSF/ANSI standard 61 60°C (140°F); 3” certified to NSF/ANSI standard 61
Cold Water 23°C (73.4°F)
EnvironmentalNEMA 6P, IP68 (10ft (3m) depth, continuously)

Modbus is a registered trademark of Schneider Electric.
* Specifications subject to change. Please consult our website for the most current data (www.seametrics.com).

¹ If forward and reverse flow data needs to be sent to another device, either the Digital or Modbus output is required.

² Rate Time Unit is available in Day only.