Flow rate Monitor and Totalizer Fluidwell F018

Flow rate Monitor and Totalizer Fluidwell F018


The flow rate monitor F018 is a local indicator/transmitter with linearization, that displays the actual flow rate, resettable total, and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly indicators. The F018 is even more impressive. The HART communication allows you to communicate in an easy way with smart "DD enabled host" systems.

In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range, even for very low-frequency applications. This linearization affects all displayed information as well as the signal outputs.

Advantages

  • Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / NEMA Type4X).
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Features

  • Displays total and flow rate simultaneously.
  • Fifteen point linearization of the flow curve - with interpolation.
  • Two-alarm values can be entered: low and high flow rate alarm.
  • Large digit selection for flow rate or total.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total.
  • Red flashing LED backlight in case of a flow rate alarm; intensity adjustable.
  • Displays clear alarm messages.
  • Scaled pulse output reflecting the accumulated total.
  • Intrinsically safe according to ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high-grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with a clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.
  • F018 on the HART Foundation website.

Applications

  • Flow rate monitor with a precise calculation over the full measurement range, where re-transmission of the totalizer and monitoring of the flow rate function and HART communication is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs
    • Flowmeter Inputs
      • Pulse-type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • Signal Outputs
    • Pulse outputs
      • Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).
        Max. frequency: 500Hz.
        Adjustable pulse length from 1 msec. to 10 seconds.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
    • Alarm outputs
      • Function: Configurable alarm output for high, low or both combined flow rate alarms.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
    • Analog outputs
      • Function: Re-transmitting the linearized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
      • Type: One galvanically isolated, loop-powered 4 – 20mA output.
  • Supply
    • Power Supply
      • Long-life Lithium battery.
      • 16 – 30V DC.
      • Basic: 8 - 30V DC.
      • Analog output loop powered.
    • Sensor Supply
      • 1.2 / 3.2 or 8.2V DC.
  • Hazardous Area
    • Intrinsically Safe
      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T100°C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T100°C Da
      • CSA:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4
      • FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4
    • Explosion Proof
      • For Explosion Proof applications we recommend the E-Series.
  • Communication
    • Function: All process data and settings can easily be read and modified through the HART communication link with all registered "DD enabled host" systems.
    • Protocol: HART, Revision 7.0.
    • Device-specific DD can be downloaded at the dropdown downloads above.

Download Datasheet: Fluidwell F018 Flow Rate Monitor and Totalizer