IMP+ I.S. is a combined transducer and controller in one self-contained unit and is I.S. certified to ATEX EEx ia IIC T4 and IECEx.
IMP+ I.S. benefits from a specially designed digital echo processing technique and is available in three versions, 3m, 6m or 10m range. The full IMP range is available with the wetted parts in PVDF build alternative for corrosive or aggressive applications.
Simple installation
IMP+ I.S. is easy to install, just simply screw into a 1.5" or 2" universal fitting (a 1.5" or 2" adapter is available). Programming is also straightforward by simply using the LCD display and integral keypad featured on the IMP+ I.S.
IMP+ I.S. Options
IMP+ I.S. is also available with the wetted parts in PVDF build alternative for corrosive or aggressive applications.
Another Article: |
Features
- 4 digit LCD display
- 4 button keypad for parameter entry
Specifications
Physical
Dimensions: | 186mm ø height x 133mm ø diameter (5.24 x 7.32in) |
Cable entry: | 2 off cable glands 4.5 -10mm (Torque to 2NM) |
Mounting: | 1.5” BSP/NPT (IMP3 & IMP6), 2” BSP/NPT (IMP10) |
Weight: | Nominal 1kg (2.2lb) |
Variants
Model: | Measurement range: | Operating frequency: | Beam angle (-3dB half power): |
IMP3 | 0.2 - 3m (0.66 - 10ft) | 125kHz | <10° inclusive |
IMP6 | 0.3 - 6m (0.98 - 20ft) | 75kHz | <10° inclusive |
IMP10 | 0.3 - 10m (0.98 - 33ft) | 41kHz | <10° inclusive |
Environmental
Enclosure protection: | IP67 |
Max. and min. temperature (ambient): | -40°C to +65°C (-40°F to +149°F) |
Max. and min. temperature (process): | -40°C to +80°C (-40°F to +176°F) |
Approvals
CE approval: | Listed in the Certificate of Conformity within the manual |
ATEX approval: | Ex II 1G EEx ia IIC T4 (Tamb = -40°C to +80°C) |
Performance
Input voltage range: | 11-30V, 3.5-22mA |
Accuracy: | ±0.25% or 6mm (0.24in) whichever is greater |
Resolution: | ±0.1% or 2mm (0.08in) whichever is greater |
4-20mA outputs: | Resolution 5µA (both active and passive outputs) |
Temperature compensation: | Via internal temperature sensor (±0.5°C accuracy). Level and volume conversion are installed allowing linearisation for tank shapes. |
PC Interface: | All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on screen. |
Download Datasheet: IMP+ I.S. Pulsar ATEX Level Sensor
Reference : pulsar-pm.com