IMP Lite can be used wherever you need reliable non-contacting ultrasonic level measurement and digital echo processing means IMP Lite is perfect for slurries or liquids and anywhere you need a display telling you the level, or an analogue output to interface with your site control system or drive a display. The full IMP range is available with the wetted parts in PVDF build alternative for corrosive or aggressive applications.
Compact and low-profile
When used on battery power for intermittent (wake-up) applications, IMP Lite's high speed boot up of circa 3 seconds maximises battery life. For example, if an IMP Lite were switched on every 15 minutes for a 3 second reading, average current is a mere 40µA.
Active and passive (sourcing and sinking) analogue outputs assist with system integration, especially when retro-fitting into older installations.
Features
- 2-wire configuration
- RJ11 Port
- Up to 10m range available
Specifications
Physical
| Dimensions: | 175mm (6.9in) overall height x 130mm (5.12in) diameter |
| Cable Entry: | 2 off 16mm (0.63in) cable glands 3.5-10mm (0.14-0.39in) cable dia |
| Mounting: | 1.5” (3m/10ft) and 6m/20ft) range versions), 2” (10m/33ft version) universal thread - suits BSP and NPT, parallel and tapered |
| Weight: | Approximately 1kg (2.2lbs) |
Environmental
| Temp. range (process): | -40ºC to +80ºC (-40ºF to +176ºF) |
| Temp. range (ambient): | -20ºC to +65ºC (-4ºF to +149ºF) |
| IP Rating: | IP67 |
Variants
| IMP3 | |
| Beam Angle (-3dB half power): | <10º inclusive |
| Operating Frequency: | 125kHz |
| Measurement Range: | 0.2-3m (0.66ft-10ft) |
| IMP6 | |
| Beam Angle (-3dB half power): | <10º inclusive |
| Operating Frequency: | 75kHz |
| Measurement Range: | 0.3m-6m (0.98ft - 20ft) |
| IMP10 | |
| Beam Angle (-3dB half power): | <10º inclusive |
| Operating Frequency: | 41kHz |
| Measurement Range: | 0.3m-10m (0.98ft-33ft) |
Performance
| Input Voltage: | 11-30V, 3.5 - 22mA |
| Accuracy: | ±0.25% or 6mm/0.24in (whichever is greater) |
| Resolution: | ± 0.1% or 2mm/0.08in (whichever is greater) |
| 4-20mA Outputs: | Resolution 5µA (both active and passive outputs) |
| Temperature Compensation: | Via internal temperature sensor (±0.5ºC accuracy). Level and volume conversion are installed allowing linearisation for tank shapes |
| 2-wire Configuration: | RS232 (RJ11 port) connection for diagnostics and software updates 4 digit LCD display 4 button keypad for parameter entry Power consumption: 3.5 - 22mA Passive 4-20mA output No flammable atmosphere approval |
| PC Interface-PC Suite: | All parameters can be accessed and changed through PC Suite software. Echo traces may be viewed on screen. |
Download Datasheet: IMP Lite Pulsar Level Measurement
Reference : pulsar-pm.com
Another Article:
dBi Profibus PA Transducer Series
Ultrasonic Liquid Level Switch 003 Series Delta Mobrey
Pulsar's Ultimate Controller