The QUICKTEMP TP62 temperature sensor has 2 transmitters in the connection head, which may, for example, be used for indication and registration purposes. In addition, QA tests, repair and maintenance work are possible without having to interrupt the process and open the measuring point. The entire device, including the connection head and measuring insert can be taken out of the process without loosening the electrical cables. This saves time and resources and creates process security.
The measuring insert is a double PT100 sensor with spring bearings and metallic contacts to ensure good heat transmission and short response times. The design of the Quicktemp system is based on one basic device with various fitting lengths or process connections, assuming defined fitting lengths. For the user, this guarantees a high degree of flexibility, while at the same time minimising the storage costs.
The two standard TE42 transmitters installed have an mA output and can be programmed via the set-up plug. The connection head in the PA is robust and resistant to external environmental conditions (protection class IP 66); it ensures good access, including the cabling of the transmitters.
Features:
- double transmitter (4-20 ma or hard output with 2-wire technology)
- quality assurance tests and retooling without process interruption and without loosening the electrical wiring.
- exchangeable measuring insert with spring bearings and metallic contact.
- various designs for appropriate installation, adaptation to existing measuring points without design changes.
- quick response times due to tapered sensor tips
Specification:
General details | ||||
Device type/measuring principle | TP62...T500 / Pt100 resistor | |||
Measuring insert | ||||
Sensor type | - 2x Pt100 in accordance with EN 60751, 3-wire | |||
Version | - Standard version tmax=400°C | |||
- Mineral-insulated version tmax=600°C, vibration resistant | ||||
Dimensions | Length 154mm (with T500), Ø=3mm | |||
Output | ||||
Version | - Temperature transmitter - 2X TE42, 4...20mA, 2-wire (standard) | |||
Transmitter TE42 | ||||
Supply voltage | 10 to 35 VDC | Temperature drift | ≤ ± 0.01% | |
Current requirement | ≤ 3.5mA | Calibration temperature | +25°C ± 5K | |
Current limitation | ≤ 23mA | Ambient temperature | -40...+85°C | |
Switch-on delay | 4s | Configurable start of range | < 50% final value | |
Response time | 1s | Attenuation | 0...60s, configurable | |
Fault signal | ≤3.6mA / ≥21mA, configurable | Vibration resistance | 4g / 2...150Hz (according to IEC | |
60068-2-30) | ||||
Voltage change influence | ≤ ± 0.01%/V of 24V FS | Protection class | IP00 (installed, see housing protection | |
class) | ||||
Circuit type | 2-wire | Climate class | Cl. C, EN60654-1 | |
Output signal | 4...20mA or 20...4mA, 2-wire | CE conformity | EN 61326-1 | |
Load resistance | (Vref-10V)/0.022A | Measuring accuracy (typical | 0.2K or 0.08% | |
values) | ||||
Long-term stability | ≤ ± 0.1K/year (under reference condi- | Measuring current at sensor | < 0.6mA | |
tions) | (normal) | |||
Linearity error | ≤ ± 0.1%/K | max. sensor cable resistance | 11Ω/wire | |
Burden influence | ≤ ± 0.02%/100Ω FS | Wire compensation with 2-L | ||
Measuring range | Type | Pt100, 2L / 3L / 4L | min. temperature | -200°C |
min. temperature span | 10K | max. temperature | +650°C | |
Connecting terminals | Screw clamps (captive screws), wires up to 1.75mm² or 1.5mm² with wire-end ferrules | |||
Measuring accuracy | ||||
Pt100 class in accordance with EN 60751 | - A (Standard) | |||
- AA (1/3B) | ||||
Response times | T50≤4…6sec or shorter (design-dependent), other information on request | |||
Conditions of use | ||||
Medium temperature | -50...400°C (standard), -50...600°C (version with mineral-insulated measuring insert) | |||
Ambient / storage conditions | - -40...+85°C (increased risk of cable breaks at less than -20°C) | |||
- Humidity 95%, without condensing (depending on transmitter used) | ||||
Protection class acc. to EN60529 IP 67 and IP 69K (depending on design) | ||||
Structural design - basic device | ||||
Electrical connection | Round plug-in connector M12x1, 4-pin, nickel-plated brass (stainless steel available on request) | |||
Process connection | Quicktemp with screw-in thread G¼“ - for protective sleeves with collar and loose union nut G¼“ | |||
Seal | Captive O-Ring seal | |||
Materials | - Field housing / lid: | CrNiSt 1.4301 (304) | ||
- Housing seal: | FPM (Viton®) | |||
- Measuring insert: | CrNiSt 1.4571 | |||
- O-Ring seal: | FKM | |||
Structural design - protective | sleeves | |||
Process connection | - Clamp connection | |||
- Weld-in solutions | ||||
- Conical coupling / threaded coupling DIN 11851 | ||||
- Female union / threaded coupling DIN 11864-1 | ||||
- VARIVENT® type N, type F | ||||
- 1“ ISO 228 thread | ||||
- Other connections such as elastomer-free sealing systems, Ingold connectors, 1“ ISO 228 thread, ... | ||||
Materials | - Sleeve body and collar CrNiSt 1.4404 | |||
- Union nut CrNiSt 1.4305 | ||||
Shape of tip | - Standard | |||
- Tapered | ||||
Max. process pressure | Depending on design, min. PN10 (optionally up to PN80, pay attention to design) | |||
Accessories for Quicktemp TP62...T500 | ||||
Configuration kit | TZ42-USB with HengCom software (as download at www.hengesbach.com) | |||
Certificates | Calibration certificate, conformity declaration, material products in accordance with EN 10204 |
Download Data Sheet:Resistance Thermometer TP 62