Bamo Flow sensor, Vortex type VORTEX

Bamo Flow sensor, Vortex type VORTEX

Bamo Measures Sas has been founded in 1978. Its capital is now 400 000 Euros. Since the beginning, the company has undergone a rapid development centring on industrial pH-meters and conductivity meters. Bamo is now well-known as a leader on the French market.

Since 1990, new developments in the Level Measure have given a new spring in the export. To its own production range, the company holds numerous agencies of foreign companies in Europe and all over the world. So we are offering a complete line with always the best possible service.

Bamo is a company that comes from France. This company selling some product. The product of Bamo such as pH and ORP; Chlorine, disinfection; Data processors; Conductivity; Water hardness; Turbidity; Oxygen; Level; Temperature; Flow; Pressure; Plastic valves; Metal valves.

Flow sensor, Vortex type VORTEX

This flow meter, which has no moving mechanical parts, is not affected by a pollution. It is distinguished by a low pressure drop and a good accuracy. The flow sensor is based on the principle of Karman vortex trail. The frequency of vortices generated by the obstacle located in the flow path, is proportional to the flow speed. Turbulence are detected by a piezoelectric paddle, operated by an integrated electronics.

Features:

  • Flow-rate sensor for domestic hot water, drinkable water, demineralised water
  • Measuring range from 0.9 to 150 l/min
  • Pipes from ND 8 to ND 25 mm
  • Output signal: or 4-20 mA or pulses
  • Drinkable water approvals: WRAS,ACS

Application:

Flow measurement on domestic hot water, drinkable water or non-conductive liquids such as demineralised water or reverse osmosis water.

Another Article:

Specification:

Measuring rangeFrom 0.9 up to 150 l/min Flow-rate < 50% F.S.: ± 1% F.S.
AccuracyFlow-rate > 50% F.S.: ± 2 %
Response timeF.S. Analogue output: < 500 ms Frequency output: < 5 ms
  

Operating conditions:

 
LiquidsDomestic hot water, potable water, demineralized water < 125
Liquid temperature limit°C
Ambient temperature limits-15 ... +85 °C
Storage temperature-30 ... +85 °C
Pressure limits vs. TemperatureMax. 12 bar at 40 °C / Max. 6 bar at 100 °C (Max. test pressure is 18 bar at 40 °C)
CavitationRespect the following relation to prevent cavitations

[ Outlet Pabs. / Differential pressure ] > 5.5


Wet parts FDA compliant:

ETFE
Sensor paddle
Body with damming insertPA6T/6I (40 % FV)
SealingEPDM peroxide (FPM on request)

Download Data Sheet: Flow sensor, Vortex type VORTEX

Ref: bamo.eu

Berbagi:  