McCROMETER VM V-Cone

The McCrometer VM V-Cone System ... Measurement Simplified

Designed to Make Flow Measurement Easy

The VM V-Cone System has an advanced differential pressure flow sensing design. The flow meter features built-in flow conditioning for superior accuracy. The VM V-Cone is the ideal new or retrofit flow meter for multiple clean water and wastewater treatment applications.

With its built-in flow conditioning technology, the V-Cone also can be placed in relatively close proximity to elbows, valves, pumps, pipe U's, etc., where other flow measurement technologies would be impractical or inaccurate.

VM V-Cone System's pre-packaged, built-in 3-way valve isolates the transmitter from the process fluid flow for easy maintenance. No need to shut down the pipeline. The flow meter arrives wet-flow calibrated direct from the factory. The ready-to-install VM V-Cone System reduces many headaches of adding a flow meter to most flow installations.

Features

Applications

The VM V-Cone System acts as its own flow conditioner, fully conditioning and mixing the flow prior to measurement. Readings are always precise and reliable, even under changing flow situations in the following Municipal and Industrial water applications:

  • Well Water Production
  • Raw Water Influent
  • Filter and Pipe Galleries
  • Finished Water Effluent
  • Collection and Distribution Systems
  • Facilities Distribution
  • Cooling Water
  • Reclaimed Water

Benefits

  • Plug and play design
  • Installs virtually anywhere in the system - even in tight spaces
  • Displays both rate of flow and total flow. Rate and total functions are independent of each other
  • allowing for many different combinations of flow units.
  • Local rate and total display on meter head
  • Remote display available for panel mounting
  • Accuracy of ±0.5% of rate
  • Flow range : 10:1
  • Installation : typically 0-3 diameters upstream and 0-1 diameter downstream
  • Totalizer pulse and linear 4-20 mA dc outputs
  • No parts to wear so little maintenance required
  • HART™ Interface
  • 3-way manifold for isolating the transmitter
  • Modbus, Profibus, Fieldbus available
  • Offering local and remote mounted displays gives maximum flexibility.

Specifications

  • Accuracy : ±0.5% of reading over standard flow range
  • Certifications : The VM V-Cone System is ISO 9001:2015 Certified
  • Head Loss : ≤2 psi at Full Scale
  • Output : Analog 4-20 mA
  • Power : 24 VDC, Remote Display 110 VAC
  • Pressure Range : 150 psi, 300 psi
  • Temperature Range : Maximum Temperature: (Standard Construction) 180ºF constan
  • Power : 24VDC, Remote Display 110 VAC
  • Outputs : Analog 4-20mA
  • Optically Isolated Pulse Output For Remote Totalization
  • Transmitter Housing : IP67
  • Display Enclosure : NEMA 4X (IP66)
  • Materials : Remote mount display includes 25 feet of power/signal
    cable. For additional length, please consult factory.
  • Body : 6-inch & larger: Fusion-bonded epoxy coated carbon steel, 4-inch & smaller: All 304 stainless steel
  • Measuring Element :  304 stainless steel

Download Datasheet: McCROMETER VM V-Cone

Reference : mccrometer.com

Another Article: 

McCROMETER Wafer Cone
McCROMETER V-Cone Flow Meter
Differential Pressure Switch 301 Series Delta Mobrey
Differential Pressure Transmitter DPR-2200 Series Delta Mobrey
Differential Pressure Flow Meter

 

Berbagi:  

Komentar

Articles