Guard door monitors and Safety control modules for Emergency Stop
applications / Micro Processor based safety controllers (Series AES) /
AES 123x
(Minor differences between the printed image and the original product may exist!)
• Monitoring of BNS range magnetic safety sensors
• 2 safety contacts, STOP 0
• 2 Signalling outputs
(Minor differences between the printed image and the original product may exist!)
• Monitoring of BNS range magnetic safety sensors
• 2 safety contacts, STOP 0
• 2 Signalling outputs
| Classification | |
| Standards | EN ISO 13849-1, IEC 61508 |
| PL | up d |
| Control category | up 3 |
| PFH value | 1.0 x 10-7/ |
| - notice | up to max. 50.000 switching cycles/year and at max. 80% contact load |
| SIL | 2 |
| Mission time | 20 Years |
| Global Properties | |
| Permanent light | AES 123x |
| Standards | IEC/EN 60204-1, IEC 60947-5-3, IEC 61508, BG-GS-ET-14, BG-GS-ET-20 |
Compliance with the Directives (Y/N) ![]() | Yes |
| Climatic stress | EN 60068-2-3, BG-GS-ET-14 |
| Mounting | snaps onto standard DIN rail to EN 60715 |
| Terminal designations | IEC/EN 60947-1 |
| Materials | |
| - Material of the housings | Plastic, glass-fibre reinforced thermoplastic, ventilated |
| - Material of the contacts | , 0,2 µm gold flashed |
| Weight | 160 |
| Start conditions | Automatic or Start button |
| Start input (Y/N) | No |
| Feedback circuit (Y/N) | Yes |
| Start-up test (Y/N) | No |
| Reset after disconnection of supply voltage (Y/N) | Yes |
| Automatic reset function (Y/N) | Yes |
| Reset with edge detection (Y/N) | No |
| Pull-in delay | |
| - ON delay with automatic start | adjustable 0,1 / 1.0 |
| Drop-out delay | |
| - Drop-out delay in case of emergency stop | < 50 |
| Mechanical data | |
| Connection type | Screw connection |
| Cable section | |
| - Min. Cable section | 0,25 |
| - Max. Cable section | 2.5 |
| Pre-wired cable | rigid or flexible |
| Tightening torque for the terminals | 0,6 |
| Detachable terminals (Y/N) | No |
| Mechanical life | 20.000.000 operations |
| Electrical lifetime | 150.000 operations for 230 VAC, 5 A (cos φ = 1) |
| restistance to shock | 30 g / 11 ms |
| Resistance to vibration To EN 60068-2-6 | 10…55 HZ, Amplitude 0,35 mm, ± 15 % |
| Ambient conditions | |
| Ambient temperature | |
| - Min. environmental temperature | 0 |
| - Max. environmental temperature | +55 |
| Storage and transport temperature | |
| - Min. Storage and transport temperature | −25 |
| - Max. Storage and transport temperature | +70 |
| Protection class | |
| - Protection class-Enclosure | IP40 |
| - Protection class-Terminals | IP20 |
| - Protection class-Clearance | IP54 |
| Air clearances and creepage distances To IEC/EN 60664-1 | |
| - Rated impulse withstand voltage Uimp | 4.8 kV |
| - Overvoltage category | III To VDE 0110 |
| - Degree of pollution | 2 To VDE 0110 |