The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme consists of two series:
- MBS 1200 – without integrated pulse-snubber
- MBS 1250 – with integrated pulse-snubber
The integrated pulse-snubber offers a high degree of protection against cavitations and liquid hammer, and the well thought out design results in excellent vibration stability and an exceptional robustness.
The high degree of EMI protection equips the pressure transmitter to meet most requirements.
Danfoss MBS series | OEM Pressure Transmitters
Features
- Designed for use in severe OEM applications
- For medium and ambient temperatures up to 125 °C
- All standard output signals:
4 – 20 mA, 0 – 5 V, 1 – 5 V, 1 – 6 V,
0 – 10 V, 10 – 90% ratiometric voltage - Wetted parts made of stainless steel
- A wide range of pressure and electrical connections
- EMC protection up to 100 V/m
- Dual output transmitter – for further information please contact Danfoss
Applications
Cavitation, liquid hammer and pressure peaks may occur in liquid filled systems with changes in flow velocity, e.g. fast closing of a valve or pump starts and stops. The problem may occur on the inlet and outlet side, even at rather low operating pressures. The media viscosity has only little effect on the response time. Even at viscosities up to 100 cSt, the response time will not exceed 4 ms.
Approvals
- UL 508 recognized
- ISO 7637 pulse 1 - 4
Another Article: |
Technical Data
Performance (EN 60770)
Accuracy (incl. nonlinearity, hysteresis and repeatability) | ± 0.5% FS |
Thermal zero point shift | <± 0.15% FS / 10K |
Thermal span shift | <± 0.15% FS / 10K |
Response time liquids (10 – 90%) | > 0.5 ms |
Durability, P: 10 – 90% FS | >10 × 10⁶ cycles |
Overload and burst pressure – without pulse-snubber (MBS 1200)
Nominal pressure [bar] | 10 | 16 | 25 | 40 | 60 | 100 | 160 | 250 | 400 | 500 | 600 | 1000* | 1600* | 2200* |
Overload pressure | 30 | 48 | 80 | 80 | 140 | 200 | 320 | 500 | 800 | 1400 | 1400 | 2000 | 2500 | 3000 |
Burst pressure | 400 | 640 | 800 | 800 | 1400 | 2000 | 1600 | 2500 | 4000 | >4000 | >4000 | >4000 | >4000 | >4000 |
* Only available with M12 × 1 1.5 P high pressure port, type FC06. Please contact Danfoss.
Overload and burst pressure – with integrated pulse-snubber (MBS 1250)
Nominal pressure [bar] | 10 | 16 | 25 | 40 | 60 | 100 | 160 | 250 | 400 | 500 | 600 |
Overload pressure | 30 | 48 | 120 | 120 | 210 | 300 | 480 | 750 | 1200 | 2100 | 2100 |
Burst pressure | 400 | 640 | 800 | 800 | 1400 | 2000 | 1600 | 2500 | 4000 | >4000 | >4000 |
Electrical specifications
Nom. output signal (Short-circuit protected) | 4 – 20 mA (2 wire) | 0 – 5, 1 – 5 1 – 6 V | 0 – 10 V | 10 – 90% ratiometric |
Supply voltage [UB], polarity protected | 8 – 30 V | 8 – 30 V | 12 – 30 V | 5 V ± 0.5 V |
Supply – current consumption | – | 4.5 mA | 4.5 mA | 4.5 mA |
Output impedance | – | ≤ 90 Ω | ≤ 90 Ω | ≤ 90 Ω |
Load [RL] (connected to 0 V ) | See chart below | RL ≥ 10 kΩ | RL ≥ 10 kΩ | RL ≥ 5 kΩ |
Load [RL] (connected to + V ) | See chart below | Not possible | Not possible | RL ≥ 5 kΩ |
Reference : danfoss.com
Contact us : sales@wmablog.com or visit to our E-Commerce
Download Datasheet : Danfoss MBS series, OEM Pressure Transmitters
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :