E2FQ, Omeron-Chemical-resistant Proximity Sensor
These Proximity Sensors use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models. OMRON Sensing Components detect, measure, analyze, and process various changes that occur on productions sites, such as changes in position, length, height, displacement, and appearance. They also contribute to predicting and preventing future events.
Features
- Housing and mounting are made of Fluororesin resistant to chemicals.
- Maximum sensing distance: 10
Rating and Specifications
Model Item | E2FQ-X2E1 E2FQ-X2D1 | E2FQ-X5E1 E2FQ-X5D1, E2FQ-X5Y1 | E2FQ-X10E1 E2FQ-X10D1, E2FQ-X10Y1 | |
Sensing distance | 2 mm ±10% | 5 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | |
Differential travel | E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.) | |||
Standard sensing object | Iron, 12 ´ 12 ´ 1 mm | Iron, 18 ´ 18 ´ 1 mm | Iron, 30 ´ 30 ´ 1 mm | |
Response frequency * | E1 Models: 1.5 kHz D1 Models: 800 Hz | E1 Models: 600 Hz D1 Models: 500 Hz | E1 Models: 400 Hz D1 Models: 300 Hz | |
Y1 Models: 25 Hz | ||||
Power supply voltage (operating voltage range) | E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max. | |||
Current consumption | E1 Models: 17 mA max. | |||
Leakage current | D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC) | |||
Control output | Load current | E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA | ||
Residual voltage | E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y1 Models: Refer to Engineering Data on page 3. D1 Models: 3 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Indicators | E Models: Detection indicator (red), Y Models: Operation indicator (red), D Models: Operation indicator (red), Setting indicator (green) (NO only) | |||
Operation mode (with sensing object approaching) |
E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.) | |||
Protection circuits | E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge sup- pressor | |||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range | |||
Insulation resistance | 50 MÙ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Cable length: 2 m) | |||
Weight (packed state) | Approx. 70 g | Approx. 130 g | Approx. 170 g | |
Materials | Case |
Fluororesin | ||
Sensing surface | ||||
Clamping nuts | ||||
Toothed washer | Zinc-plated iron | |||
Cable | Vinyl chloride | |||
Accessories | Instruction manual |