Eltra Carbon/Sulfur Analyzer CS-580A

Carbon/Sulfur Analyzer CS-580A


ELTRA‘s CS-580A is the ideal analyzer for the simultaneous determination of carbon and sulfur in organic samples.

ELTRA’s 580A analyzers (A = Auto-loader) are equipped with an automatic sample loader, allowing for analysis of large numbers of samples without operator intervention. The sample loader is available in two versions to accommodate 36 or 130 crucibles. The CS-580A is based on the technology of the CS-580 analyzer and features a vertical resistance furnace with the ceramic tube.

The temperature can be set in steps of 1 °C to a maximum of 1,550 °C. Thanks to sample weights of up to 500 mg and more even in-homogeneous materials can be reliably analyzed. The analyzer can be equipped with up to four independent infrared cells according to the user’s requirements, allowing for a great variety of applications.

Advantages

  • Simultaneous carbon and sulfur determination with minimal sample preparation
  • A wide range of organic materials can be analyzed
  • Rapid, precise, accurate, and reliable element determination
  • Resistance furnace can be set up to 1550 °C in steps of 1 °C
  • Customized infrared cells provide a wide, dynamic measuring range
  • Due to gold IR path, increased cell live time for analysis of halogen or acid-containing samples
  • Powerful software (multilingual, customized display, the export of results)
  • Single and multi-point calibration
  • Low maintenance
  • The robust design allows usage in production control and laboratory

Application

Ashes, building materials, coal, coke, gypsum, limestone, oil, plant materials, rubber, sand, soils, soot, tobacco, waste, etc.

Another Article:

Specification

Measured elementscarbon, sulfur
Samplesorganic
Furnace alignmentvertical
Sample carrierceramic crucibles
Field of applicationagriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, medicine / pharmaceuticals
Furnaceresistance furnace (ceramic tube), adjustable up to 1550 °C (steps of 1 °C)
Detection methodsolid state infrared absorption
Number of IR cells4-Jan
The material of IR pathgold
Typical analysis time60 - 120 s
Chemicals requiredmagnesium perchlorate, sodium hydroxide
Gas requiredoxygen 99.5 % pure (2 - 4 bar / 30 - 60 psi)
 compressed air (4 - 6 bar / 60 - 90 psi)
Power requirements230 V, 50/60 Hz, max. heat up current 2000 W
Dimensions (W x H x D)55 x 100 x 60 cm (analyzer)
 85 x 35 x 45 cm (Autoloader for 130 crucibles)
Weight~ 90 kg (analyzer)
 ~ 15 kg (Autoloader for 130 crucibles)
Required equipmentbalance (resolution 0.0001g), monitor, PC
Required accessoriesAutoloader (for 36 or 130 crucibles)
Optional accessoriesTIC module, voltage stabilizer 5 KVA

Download Data Sheet: Carbon/Sulfur Analyzer CS-580A

Ref: eltra.com