The TPF pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The wide range of hygienic process connections enables use in all applications in the food and pharmaceutical industries. Customer-specific process connections are also possible on request.
The vacuum-proof measuring cell with stainless steel membrane works on the basis of the piezoresistive measuring principle The TPF pressure transmitters are designed to measure from -1/0…0.35 to -1/0…100 bar. Special measuring ranges are also available on request. Given the nature of the design for long-term medium temperatures of up to 125°C / 200°C, CIP and SIP cleaning methods can be used on the transmitters. The high protection classes of IP67 and IP69K also mean that the devices can be safely cleaned on the outside with foam and a high-pressure cleaner and that moisture is reliably prevented from entering into the device.
Features:
- precise measurements with ≤ ± 0,15% FS
- wide range of process connections for hygienic applications
- TurnDown 10
- vacuum-proof piezoresistive measuring cell with stainless steel membrane
- measuring ranges from 100mbar
- easy to clean an high protection classes IP 67 und IP69K
- integrated on-site display or external OPUSM display and operating module for parametrization and display of measuring values
- application strengths: measurement of content of pressured tanks / vacuum measurements with high temperatures
Specification:
General details | ||||
Device type / measuring principle | TPF 100/101: piezoresistive | |||
Input | ||||
Measuring ranges | TPF 100/101 | |||
Standard nominal measuring ranges [bar] | relative | OP | absolute | OP |
OP = overload protection [bar] | 0...0.35 | 1 | ||
0...1 | 3 | 0...1 | 3 | |
-1/0...2.5 | 8 | 0...2.5 | 8 | |
Special measuring ranges are | -1/0...5 | 15 | 0...5 | 15 |
-1/0...10 | 30 | 0...10 | 30 | |
All measuring cells are vacuum-proof | ||||
-1/0...30 | 90 | 0...30 | 90 | |
-1/0...100 | 250 | 250 | 250 | |
Setting the measuring ranges | Via the keypad of the OPUSM display and operating module / via the integrated on-site display | |||
Setting ranges | Start the measuring | zero: | 0...90% | of the sensor's nominal measuring span |
Measuring span span: | 10...100% | of the sensor's nominal measuring span | ||
Burst pressure DIN16086 | ≥ 4-fold measuring range | |||
Output | ||||
Output signal | 2-wire: 4...20mA with a test circuit connection in the device | |||
Fault signal | Optional: 3.8mA, 22mA, hold (i.e. holding the last value) | |||
Current limitation | 3.85mA and 21.5mA (normal operation) | |||
Integration time | Continuously selectable between 0 and 300s (setting time after a pressure leap) | |||
Measuring accuracy | ||||
Reference conditions | acc. to DIN IEC 770 | |||
Linearity, hysteresis and repeatability as per the limit point method DIN IEC 770 | ≤ ± 0.15% of the sensor's nominal measuring range | |||
Activation time | < 5 s (the device will carry out a self-test.) | |||
Setting time (without damping) | < 200ms | |||
Long-time drift | ≤ 0.2% of the span per year | |||
Thermal hysteresis | ≤ ± 0.75% beginning of the measuring range / ≤ ± 0.8% end of the measuring range (VRM) | |||
≤ ± 0.2% of the sensor's nominal measuring range / 10K (-20... | +80°C) from 4 bar (PZM) | |||
≤ ± 0.3% of the sensor's nominal measuring range / 10K (-20... | +80°C) up to 0.6 bar (PZM) | |||
Conditions of use | ||||
Installation position / calibration position | Any position / standing vertically (position-dependent zero point displacement) | |||
Medium temperature | T1: -40 to +125°C (140°C over one hour at the most) | |||
T2: -40 to +200°C (high-temperature version) | ||||
Ambient storage temperature | Type 101: | -40...+85°C | ||
Type 100: | -30...+75°C | |||
(Below -20°C cable breakage might occur and the display's function may be impaired.) | ||||
Protection class acc. to EN60529 | IP 67 and IP 69K | |||
Electromagnetic compatibility | Sensitivity against interference: acc. to DIN IEC 61000-6-2 | |||
Interference radiation: | acc. to DIN IEC 61000-6-4 | |||
Construction | ||||
Electrical connection | - Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request | |||
- Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request | ||||
- Optional: angle plug acc. to EN 175301-803 | ||||
- Optional: reference cable | ||||
Process connection | - All standard front-mounted process connections and those that are commonly used by the manufacturer | |||
- Membrane, flush-welded on the front, CrNiSt, other materials available on request |
Download Data Sheet: Pressure and Level Transmitter TPF 100/101
Ref: Hengesbach.com
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :