Hengstler Safety Relays Type 466

Hengstler Safety Relays Type 466
Safety Relays Type 466[/caption]

To ensure that our relays as used in your applications carry on doing their job reliably for years, the quality of products bearing the HENGSTLER name is the highest priority. All our locations are certified to ISO 9001 and ISO 14001, and the entire product range is, as you would expect, in conformity with RoHS and REACH regulations. For decades, HENGSTLER has been intensively involved in matters relating to forcibly guided, or captive, contacts and, as a result, with safety relays. Our large, international customer base benefits from this experienced gathered over many years when it comes to developing and manufacturing relays with forcibly guided contacts.

With its H-466 safety relays, HENGSTLER provides a solution for all those applications that involve a high number of electric switching contacts. At the same time, the max. installation height of 20.5 mm enables a high component density to be achieved. The safety relay is designed for the highest possible degree of reliability, robustness and a long electrical life-time. As a result, these safety relays can be used wherever high availability is essential, even at high switching loads. The drive system can be supplied as a monostable version either for DC or AC. In addition, the H-466 relay is available as a DC bistable version. For special applications, it is possible to quote solutions in which the load current is fed direct to the relay coil, which enables the correct functioning of the load to be monitored. H-466 safety relays conform to EN 50205 standard, Application type A, and IEC EN 61810-1. In addition, these safety relays also meet the requirements for railway signal relays in accordance with UIC 736e.

Features

  • 4, 6, 8 or 10 contacts
  • 10 A switching and constant current
  • Drive available as DC monostable, DC bistable and as load-current controlled
  • Ambient temperatures -25 to +80 °C
  • Forcibly guided contacts to EN 50205, Application type A
  • Meets requirements for signal relays under UIC 736e
  • cULus and TÜV approvals

Specification

Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family466
Contact setforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered withSn 100
ApprovalTÜV
 cULus
StandardsEN 50205
 IEC 61810-1
 UL 508
Meets the requirementsRoHS
 UIC 736
Shipment inclusive2 pcs. mounting brackets
Number of NO contacts2 ... 8
Number of NC contacts1 ... 7
Number of CO contacts0
Size4-Mar
Dimensions L x W x H [mm]Size 1: 57,7 x 66,5 x 20,5 mm
 Size 2: 67,4 x 66,5 x 20,5 mm
 Size 3: 77,4 x 66,5 x 20,5 mm
 Size 4: 87,4 x 66,5 x 20,5 mm
Housingdustproof (RT II)
 washtight (RT III)
Shock resistance NO / NC [g]10/10 g
Puls duration (half sinus)16 ms
Vibration resistance NO / NC [g]10/10 g
Frequency range [Hz]10 - 55 Hz
Operating time NC contact, contact opens [ms]17 - 22 ms
Operating time NO contact, contact closes [ms]23 - 29 ms
Releasing time NO contact, contact opens [ms]5 ms
Releasing time NC contact, contact closes [ms]7 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection typeSolder pins for pcb
 Coil: Wire
Fixing typeContact: Solder pins