Kobold DPE Turbine Wheel Flow Meter





The KOBOLD flowmeter model DPE is used for measuring and monitoring liquids. The device works according the well-known blade wheel principle. The six vane blade wheel is retained axially in a high quality sapphire bearing. The sensor is supplied ready-to-install with pipe fittings or with weld-on sleeves. The blade wheel is set in motion by the flowing medium. Magnets are embedded hermetically sealed in the ends of the blade wheels. The magnets generate electrical pulses in a Halleffect sensor mounted outside the flow area.




Features

Fields of applications

  • cooling water monitoring
  • general mechanical engineering
  • waste water treatment
  • all heavy goods industry
  • chemical industry

Specifications

Technical Details

  • Measuring accuracy: ±2.5% of full scale
  • Process temperature: max. 80°C
  • Ambient temperature: max. 80°C
  • Max. operatingpressure: PN40 / 20°C
  • Max. pressure loss:
    DPE-...05: 0.05 bar
    DPE-...10, ...15: 0.03 bar
    DPE-...20: 0.04 bar
    DPE-...25: 0.02 bar
    DPE-...30: 0.01 bar
  • Protection: IP65

Materials

  • Housing: brass
  • stainless steel 1.4581
  • Seals: brass version: NBR
  • Stainless steel version: FPM
  • Turbine wheel: PVDF
  • Axle: hard metal
  • Bearing: sapphire

Electronics

Frequency output (..F300)

  • Power supply: 12-28 VDC
  • Power consumption: 10 mA
  • Pulse output: PNP, open collector, max. 25 mA
  • Electr. connection: plug connector M12x1

Frequency output with frequency divider

  • Power supply: 24 VDC ±20%
  • Power consumption: 15mA
  • Pulse output: PNP, open collector, max. 25 mA
  • Electr. connection: plug connector M12x1
  • Division ratio: 1...1/128, factory set

Analogue output (plug-on display option)

  • Power supply: 24 VDC ±20%
  • Output: 0-20 mA or 4-20 mA, 2- or 3-wire
  • Max. load: 500 Ω
  • Electr. connection: plug connector M12x1 or DIN 43 650
  • Option: plug-on display (with plug connector
  • DIN 43 650 and 4-20 mA output only)

Compact electronics

  • Display: 3-digit LED
  • Analogue output: (0)4...20 mA adjustable, max. 500 Ω
  • Switching outputs: 1 (2) semiconductor PNP or NPN, factory set
  • Contact operation: N/C / N/O contact, frequency programmable
  • Setting: with 2 buttons
  • Supply: 24 VDC ±20%, 3-wire, approx. 100 mA
  • Electr. connection: plug connector M12x1

ADI electronics

  • Display: bar graph and 5-digit digital display
  • Analogue output: (0)4...20 mA, 0-10 VDC
  • 2 switching outputs: relay /changeover contact, max. 250 VAC/5A resistive load, max. 30 VDC / 5A
  • Setting: via 4 buttons
  • Supply: 100...240VAC ±10% or 18...30VAC /10...40VDC
  • Electr. connection: pluggable terminal block via cable gland

DPE-...Exxx (Counter electronic)

  • Display: LCD, 2 x 8 digit, illuminated total, part and flow quantities, units selectable
  • Analogue output: 0(4)...20 mA adjustable
  • Load: max. 500 Ω
  • Switching outputs: 2 relays, max. 250 V/5 A/1000 VA
  • Settings: via 4 buttons
  • Functions: Reset, Min./Max. memory, flow monitor, monitoring for part and total quantity, language
  • Supply: 24 VDC ±20%, 3-wire
  • Power consumption: approx. 170 mA
  • Electr. connection: pluggable screw terminals via cable gland

DPE-...Gxxx (Dosing electronic)

  • Display: LCD, 2 x 8 digit, illuminated total, part and flow quantities, units selectable
  • Analogue output: 0(4)...20 mA adjustable
  • Load: max. 500 Ω
  • Switching outputs: 2 relays, max. 250 V/5A/1000 VA
  • Settings: via 4 buttons
  • Functions: dosing (relay S2), start, stop, reset, fine dosing, correction amount, flow switch, total quantity, language
  • Supply: 24 VDC ±20%, 3-wire
  • Power consumption: approx. 170 mA
  • Electr. connection: pluggable screw terminals via cable gland

Download Datasheet: Kobold DPE Turbine Wheel Flow Meter

Reference : kobold.com