Kobold TUR Turbine Wheel

The flowmeters with turbine wheel serve to measure, control and regulate flowing liquids. The use of chemically highly resistant materials allows the devices to be used with acids, bases and aggressive media that are to be found in the chemical industry.



Plastic version for liquids

Measuring range: 0.2 - 5 l/min ... 2.5 - 100 m³/h water
Connection: flange DN25 ... DN100
Material: PVC, PVDF
pmax: PN10
tmax: 60°C (PVC), 70°C (PVDF)
Accuracy: ±1 % of full scale
Pulse output



Plastic version for liquids

Measuring range: 0.2 - 5 l/min ... 2.5 - 100 m³/h water
Connection: flange DN25 ... DN100
Material: PVC, PVDF
pmax: PN10
tmax: 60°C (PVC), 70°C (PVDF)
Accuracy: ±1 % of full scale
Analogue output



Plastic version for liquids

Measuring range: 0.2 - 5 l/min ... 2.5 - 100 m³/h water
Connection: flange DN25 ... DN100
Material: PVC, PVDF
pmax: PN10
tmax: 60°C (PVC), 70°C (PVDF)
Accuracy: ±1 % of full scale
Analogue output, contacts NPN / PNP, digital indicator



Plastic version for liquids

Measuring range: 0.2 - 5 l/min ... 2.5 - 100 m³/h water
Connection: flange DN25 ... DN100
Material: PVC, PVDF
pmax: PN10
tmax: 60°C (PVC), 70°C (PVDF)
Accuracy: ±1 % of full scale
Analogue output, pulse output, contacts, digital indicator

Specifications

Technical Details

  • Measuring accuracy: ±1% of full scale
  • Viscosity range: for low-viscosity media
  • Max. operating temperature: 60°C (PVC version), 70°C (PVDF version)
  • Max. operating pressure: PN 10
  • Protection type: IP 65

Electronics

Frequency output

  • Power supply: 24 VDC ±20%
  • Idle current: typ. 15 mA
  • Pulse output: PNP or NPN, max. 400 mA
  • Electrical connection: 2 m PVC cable

Transmittter

  • Power supply: 230 VAC, 24 VAC, 24 VDC
  • Output: 0-20 mA, 4-20 mA or 0-10 VDC 4-wire
  • Max. load: 500 Ω
  • Electrical connection: adapter box with cable connection

Compact electronics

  • Display: 3-segment LED
  • Analogue output: (0)4... 20 mA adjustable, max. 500 W
  • Switching outputs: 1 (2) semiconductor PNP or NPN factory set
  • Contact operation: N/C / N/O contact programmable
  • Setting: with 2 buttons
  • Power supply: 24 VDC ±20%, 3-wire technology, approx. 100 mA
  • Electrical connection: plug connector M12x1

ADI electronics

  • Display: bar graph and 5-digit digital display
  • Analogue output: (0)4...20 mA, 0-10 VDC
  • 2 switching outputs: relay /changeover contact, max. 250 VAC/5 A resistive load, max. 30 VDC / 5 A
  • Setting: via 4 buttons
  • Power supply: 100 ... 240 VAC ± 10 % or 18 ... 30 VAC /10 ... 40 VDC
  • Electrical connection: pluggable terminal block via cable gland

Download Datasheet: Kobold TUR Turbine Wheel 