Magnetrol Echotel® Model 940/941 Compact Economical Ultrasonic Level Switch

Echotel ® Model 940/941 Ultrasonic Level Switch  Echotel ® Model 940 and 941 Ultrasonic Level Switches are compact integral units that utilize pulsed signal technology to perform high or low level measurement in a wide variety of liquid applications. These switches feature a 316 stainless steel tip-sensitive transducer that is offered in a variety of NPT, flanged, and hygienic process connections. The compact electronics are completely encapsulated just above the process fitting. The Magnetrol ® Model 940 offers a 1-amp SPDT relay output. The Model 941 has a mA current shift output.       Another Article:  Magnetrol Echotel® 910 Ultrasonic Level Switch Magnetrol E3 Modulevel® Liquid Level Transmitter Pulsar Continuous Level and Volume Measurement Hengesbach Level Module for Installation in Level Probes Type NM Industrial Controller MCU 200 Series Features Features Pulsed electronics for excellent performance in difficult process conditions and superior immunity from sources of electromagnetic noise Tip-sensitive transducer gap provides reliable operation by draining viscous liquids and shedding foam in turbulent applications Safety Integrity Level (SIL) data (FMEDA analysis) is available. Model 940 is suitable for SIL 2 loops. Model 941 is suitable for SIL 1 loops. Extremely compact unit is easily installed in areas where access space is limited 1-amp SPDT relay output (940), or mA current shift (941) output No calibration required Applications  The Model 940/941 can be applied in a wide variety of high or low liquid level applications, pump protection, and fill line monitoring as shown in the diagram at the left. These compact units can also be installed in the interstitial space between two tank walls for fluid leak detection. Small size and simplicity of installation make these units ideal for OEM skids as a low cost, yet high performance level measurement solution. They are also the perfect replacement for older floats, conductivity switches, and tuning forks  Specifications Electrical: Power Supply:	 	12–35 VDC Power Consumption:	 	Less than 1 Watt Signal Output:	Model 940:	SPDT relay, 1 amp @ 30 VDC, 0.5 amp @ 125 VDC, 0.5 amp @ 150 VAC  	Model 941:	Dry Gap: 8 mA (±1 mA), Wet Gap: 16 mA (±1 mA) Cabling:	 	18" (457 mm) flying leads of 18 AWG wires Repeatability:	 	0.078" (2 millimeters) Response Time:	 	1⁄2  second typical Environmental: Ambient Temperature:	 	-40 to +185 °F (-40 to +85 °C) Process Temperature:	 	-40 to +185 °F (-40 to +85 °C) Maximum Pressure:	 	2000 psig (138 bar) for 1" (3 cm) NPT and 2" (5 cm) BSP transducers  	 	1500 psig (103 bar) for longer transducers Shock	 	ANSI/ISA-S71.03 Class SA1 Vibration	 	ANSI/ISA-S71.03 Class VC2  Download Datasheet: Magnetrol Echotel ® Model 940/941 Ultrasonic Level Switch  Reference: magnetrol.com


Echotel ® Model 940 and 941 Ultrasonic Level Switches are compact integral units that utilize pulsed signal technology to perform high or low level measurement in a wide variety of liquid applications. These switches feature a 316 stainless steel tip-sensitive transducer that is offered in a variety of NPT, flanged, and hygienic process connections. The compact electronics are completely encapsulated just above the process fitting. The Magnetrol ® Model 940 offers a 1-amp SPDT relay output. The Model 941 has a mA current shift output.

     Another Article:

Features

Features

  • Pulsed electronics for excellent performance in difficult process conditions and superior immunity from sources of electromagnetic noise
  • Tip-sensitive transducer gap provides reliable operation by draining viscous liquids and shedding foam in turbulent applications
  • Safety Integrity Level (SIL) data (FMEDA analysis) is available. Model 940 is suitable for SIL 2 loops. Model 941 is suitable for SIL 1 loops.
  • Extremely compact unit is easily installed in areas where access space is limited
  • 1-amp SPDT relay output (940), or mA current shift (941) output
  • No calibration required

Applications

The Model 940/941 can be applied in a wide variety of high or low liquid level applications, pump protection, and fill line monitoring as shown in the diagram at the left. These compact units can also be installed in the interstitial space between two tank walls for fluid leak detection. Small size and simplicity of installation make these units ideal for OEM skids as a low cost, yet high performance level measurement solution. They are also the perfect replacement for older floats, conductivity switches, and tuning forks

Specifications

Electrical:
Power Supply: 12–35 VDC
Power Consumption: Less than 1 Watt
Signal Output:Model 940:SPDT relay, 1 amp @ 30 VDC, 0.5 amp @ 125 VDC, 0.5 amp @ 150 VAC
 Model 941:Dry Gap: 8 mA (±1 mA), Wet Gap: 16 mA (±1 mA)
Cabling: 18" (457 mm) flying leads of 18 AWG wires
Repeatability: 0.078" (2 millimeters)
Response Time: 1⁄2  second typical
Environmental:
Ambient Temperature: -40 to +185 °F (-40 to +85 °C)
Process Temperature: -40 to +185 °F (-40 to +85 °C)
Maximum Pressure: 2000 psig (138 bar) for 1" (3 cm) NPT and 2" (5 cm) BSP transducers
  1500 psig (103 bar) for longer transducers
Shock ANSI/ISA-S71.03 Class SA1
Vibration ANSI/ISA-S71.03 Class VC2