Tracer 1000™ 3G LTT1-3G 3rd (up to 60ft) Radar Level Transmitter

The Tracer 1000™ 3G Guided Wave Radar Level Transmitter is ideal for level measurement of liquids, solids, bulk materials, sludge, powders, and granules. With a maximum measuring distance of 60ft. the guided-wave technology sends the radar pulse down a probe to measure either liquids or solids. The pulse hits the surface and is reflected up the probe to the sensor, where the transit time is translated into a distance using time of fight and time expansion. The amplitude of the reflection depends on the dielectric constant of the product. This technology is not affected by pressure, temperature, viscosity, vacuum, foam, dust, changes in dielectric constant, or coating of the probe.

Features and benefits

  • Interface level measurement
  • Up to (60ft. 8in) range
  • Very short minimum range (6in)
  • Simple Setup
  • Auto-calibration to any dielectric ≥ 1.5
  • Adjustable Sensitivity
  • Precise & Continuous accuracy
  • 14-28VDC
  • Modbus
  • Protection class IP66, NEMA 4x
  • Measures extremely low dielectric (1.5)
  • Programmable fail-safe mode

Technology

The Tracer 1000™ uses TDR Technology: low-energy, high-frequency electromagnetic impulses, generated by the sensor’s circuitry, are propagated along with the probe which is submerged in the liquid or solid to be measured. When these impulses hit the surface of the media, part of the impulse energy is reflected up the probe to the circuitry which then calculates the level from the time difference between the impulses sent and the impulses reflected. The sensor can output the analyzed level as a continuous measurement reading through its analog output. TDR Sensors are also known as Guided Radars or Guided Wave Radars.

Specification

 

ELECTRONICS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROVALS2

(USA) FM XP-AIS Cl. I Div 1, Grp A, B, C,

D, T6...T2B, Cl. I Zone 0/1 AEx a/d [ia Ga] IIC T6...T2 Ga/ Gb

(USA) FM DIP-AIS Cl. II/III Div 1, Grp E, F,

G, T6...T2B, Zone 20/21 AEx ia/tb [ia Da]

IIIC T85°C...T255°C Da/ Db

(Canada) FM Cl. I Div 1, Grp A, B, C, D,

T6...T2B

(Canada) FM Cl. II/III Div 1, Grp E, F, G,

T6...T2B

(Canada) FM Cl. I Zone 0/1 Ex ia/d [ia Ga] IIC T6...T2 Ga/ Gb

(Canada) FM Zone 20/21 Ex ia/tb [ia Da] IIIC T85°C...T255°C Da/ Db

ATEX Ex II 1/2 G Ex ia/d [ia Ga] IIC T6... T2 Ga/Gb

ATEX Ex II 1/2 D Ex ia tb [ia Da] IIIC T6... T2 Ga/Gb

IECEx Ex ia/d [ia Ga] IIC T6…T2 Ga/Gb Tamb -40°C to 60°C

IECEx Ex ia tb [ia Da] IIIC T85°C… T255°C Da Db Tamb -40°C to 60°C

Safety Integrity Level rating SIL2 / SIL3

 

 

POWER

-  24VDC (14 to 28VDC)

-  2-Wire Loop

 
POWER CONSUMPTION

 

<500mW @ 24VDC

 

 

 

COMMUNICATIONS

-  Modbus

-  HART

-  Tracer Software via Modbus or HART

 

 

 

ANALOG OUTPUT1

-  14V @ 0 Ohm

- 19V @ 250 Ohms

- 24V @ 500 Ohms

- Current park at 4mA, 8mA, 12mA

 

 

MAXIMUM RANGE

-  Flexible cable probe: 60ft 8in (18.5m)

-  Rigid probe: 13ft 1in (4m)

 
MINIMUM RANGE (BLANKING)

 

150mm

 
DIELECTRIC RANGE³ 1.5 
FREQUENCY2.2 GHz 

 

ENCLOSURE

 
RESOLUTION

-   Analog: 1uA

-  Display: 1.0mm

 

 

TYPE

 

Dual Compartment with Glass window

 
ACCURACY+/- 3mm 
MEASUREMENTS PER SECOND

 

3

 

 

 

MATERIAL

 

- Die-cast Copper-Free Aluminium, Epoxy Painted

-  316L Stainless

 

 

RESPONSE TIME

 

<1 second (application dependant)

 
SUM OF NON- LINEARITY, NON- REPEATABILITY, HYSTERESIS

 

 

Analog +/- 0.02%

 

 

 

CABLE ENTRIES

- 1/2” NPT

- 3/4” NPT

- M20 x 1.5

- M25 x 1.5

 
REPEATABILITY+/- 3mm 

 

MEMORY

Non-Volatile (No backup battery required)

>10 years of data retention

 

 

IP RATING

 

-  NEMA 4X

-  IP66

 
OPERATING TEMPERATURE (ELECTRONICS)

 

-40ºF to +176ºF (-40ºC to +80ºC)

 

 

PROBE

 

 

 

 

 

 

PROBE SIZE/ WETTED MATERIALS

 

4mm SS316L rod

4mm DIN3055 (7x7 strand) SS316L flexible cable

6mm SS316L rod

6mm DIN3055 (7x7 strand) SS316L flexible cable

8mm SS316L rod

8mm DIN3055 (7x7 strand) SS316L flexible cable

 

 

DISPLAY

 

4 line graphic display (128 x 64 pixels)

 
LANGUAGEEnglish 

 

CONFIGURATION

 

4 button (up-down, Cal, Run), Tracer Software via HART

 
  

Download Datasheet: Tracer 1000™ 3G LTT1-3G 3rd  (up to 60ft), Flo-corp-Generation Radar Level Transmitter