Weidmuller IT-TIMER Analogue Signal Processing

IT-TIMER

Timing relays are used in automation engineering in order to compensate for malfunctions caused by high clock rates.

Short pulses are extended and hence are reliably identified by downstream control components.

Various timing functions such as make and break delays, clock generator, and star/delta switchover are available to users.

Specifications

Dimensions and weights

Width17.5 mm
Width (inches)0.689 inch
Height98 mm
Height (inches)3.858 inch
Depth57.9 mm
Depth (inches)2.28 inch
Net weight58 g

Temperatures

Humidity25 - 75%, no condensation
Operating temperature, max.50 °C
Operating temperature, min.-25 °C
Storage temperature, max.70 °C
Storage temperature, min.-40 °C
Operating temperature-25 °C...50 °C
Storage temperature-40 °C...70 °C

 

     Another Article:

Environmental Product Compliance

REACH SVHCLead 7439-92-1

Input

Rated control voltage24...48 V DC - 15 % / + 10 % / 24...240 V AC - 15 % / + 10 %
Power rating8 VA @ 230 V AC, 0.4 W at 24 V DC
Status indicatorLED green (U/t): flashes when time runs, lights permanently with supply voltage applied, LED yellow (R): relay closed
Repeat accuracy< 0.5 % or ±5 ms
Setting tolerance5 %
Basic accuracy< 1.5 % (of scale-end value)
Min. pulse duration50 ms
Time ranges0.05 s - 1 s, 0.5 s - 10 s, 3 s - 60 s, 0.5 min - 10 min, 3 min - 1 h, 0.5 h - 10 h
Timing functionOn delay, Off-delay with control input, Single-shot rising edge with control input, Single-shot rising edge supply voltage controlled, Single-shot falling edge with control input, Clock generator pause first, Flip-flop/latching
Max. reset time after voltage interruption100 ms

Output

Rated switching voltage250 V AC
Rated switching voltage
Voltage typeAC
max.250 V
Max. switching voltage, AC250 V
Max. switching voltage, DC30 V
Continuous current5 A
Continuous current
Current5 A
AC switching capacity (resistive), max.1250 VA
DC switching capacity (resistive), max.90 W
Min. switching power10 mA @ 12 V, 100 mA @ 5 V

Contact data

Contact type1 CO contact (AgNi)
Mechanical service life1 x 106 switching cycles

General data

Versionwith separate control input
RailTS 35
Test buttonNo
Mechanical switch position indicatorNo
Resistance to vibration EN 61812-110 Hz...60 Hz: 0.15 mm, 60 Hz...150 Hz: 2 g

Insulation coordination

Rated voltage300 V
Surge voltage categoryII
Pollution severity2
Protection degreeIP20
Dielectric strength, Input/Output1.6 kV
Creepage and clearance distance input – output≥ 3 mm
Impulse withstand voltage2.5 kV

Connection data

Wire connection methodScrew connection
Stripping length, rated connection7 mm
Tightening torque, max.0.5 Nm
Clamping range, rated connection2.5 mm²
Clamping range, min.0.25 mm²
Clamping range, max.2.5 mm²
Wire connection cross section AWG, min.AWG 23
Wire connection cross section AWG, max.AWG 14
Wire cross-section, solid, min.0.25 mm²
Wire cross-section, solid, max.2.5 mm²
Wire connection cross-section, finely stranded, min.0.25 mm²
Wire connection cross section, finely stranded, max.2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.0.25 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.2.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.0.25 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.2.5 mm²
Blade sizesize PH1

Classifications

ETIM 6.0EC001439
ETIM 7.0EC001439
eClass 9.027-37-16-05
eClass 9.127-37-16-05
eClass 10.027-37-16-05

Approvals

Approvals CE, EAC
ROHSConform

Download Datasheet: Weidmuller IT-TIMER Analogue Signal Processing

Reference : weidmueller.com

Berbagi:  