FLO-CORP’s wireless cellular monitors have the ability to monitor multiple field devices of any type (i.e. level, flow, pressure, temperature, pH) and transmit the data to an online cloud-based portal for remote monitoring. The software capabilities include filtering tanks by-product, checking battery levels and network status, monitoring multiple tanks at one time, and viewing current tank inventory, inventory history, and alarm information.
The Analog Input/Output Module for the CONNEX 3D™ Flexible Meter provides the input from a variety of standard analog inputs such as flow, level, pressure, temperature, pH, and analytical inputs to standard field instruments and measurements. Analog input modules offer superior isolation and filtering for input and output to meet integrated system monitoring solutions. High data integrity for scalable measurements facilitates conversion to serial RS-485 digital communications using MODBUS RTU (Master & Slave) on three isolated communication ports. Easy plug-in connection to the CONNEX 3D™ Digital Display Module (CDDM), CONNEX 3D™ Pump and Relay Control Module (DXM1), CONNEX 3D™ TCP/IP Ethernet Module (C485), CONNEX 3D™ Data Logger and Cellular Modem Module (CELL) and CONNEX 3D™ Radio Module (CDRM) for high performance wired or wireless monitoring.
Analog Input Module CAIM Connex Compatible, Flocorp-Monitor | Descriptions
The CONNEX 3D™ is a revolutionary concept in the process instrumentation market. It is flexible, versatile, and adaptable due to the variety of modules that connect to each other. Think of the modules like Legos®, pick and choose from a wide variety of options that plug into your CONNEX 3D to create a unique system to fit your exact needs.
Another Article: |
Specification
ANALOG INPUT MODULE | ANALOG OUTPUT | 4-20mA isolated output | |||
ANALOG INPUTS | Up to 4 channels | ||||
TRANSMITTER POWER SUPPLY | 10 to 30 VDC or 90 to 240 VAC 50/60 Hz | ||||
ISOLATION | Complete Analog Out | ||||
SERIAL | 2 | ||||
RESOLUTION | 12 Bits | ||||
I/O MODE | Voltage & Analog - Current | INTERFACE | 2 RS-485 with 3-wire terminal blocks | ||
INPUT RANGE | 4 to 20 mA | PARITY | Non-Fixed | ||
ACCURACY | 0.1%FSR @25 C, 0.5%FSR@-40 and 75 C |
DATA BITS |
8 | ||
SAMPLING RATE | 1.5 samples / sec | STOP BITS | 1, 2 | ||
BUILT-IN RESISTOR FOR CURRENT INPUT |
240 ohms | BAUDRATE | 9600 to 921600 | ||
PROTOCOLS | Modbus RTU (Master, Slave) | ||||
POWER REQUIREMENTS |
10-28 VDC | ||||
Specifications are subject to change without notice. | |||||
Ref: Flo-Corp.com
Contact us : sales@wmablog.com or visit to our E-Commerce
Download Datasheet: Analog Input Module CAIM CONNEX COMPATIBLE, Flocorp-Monitor