Fluidwell F116 Differential / Sum Flow Computer

The F116 flow computer has been developed to calculate differential/consumption or total volume. The usual difficulties encountered in such applications include pulsating flows, very low consumption readings, vibration, and high ambient temperatures. These are all well-catered for in the design and operation of the F116. The pulse and analog outputs do reflect the calculated differential or sum value.

The display shows the flow rate, total, and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

Advantages :

  • Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / NEMA Type4X). It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications.
  • Familiar with easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost, and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels, or directly onto outdoor sensors.

Features :

  • Calculates differential flow rate (consumption), a total, and an accumulated total of flow A and B.
  • Calculates the sum flow rate, a total, and accumulated total of flow A and B.
  • Precautions for pulsating flows and very low consumption readings.
  • Analog and pulse outputs.
  • Displays total and flow rates simultaneously.
  • Large digit selection for flow rate or total.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total on the display.
  • LED backlight.
  • Intrinsically safe according to ATEX and IECEx.
  • GRP, Aluminum, or high-grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Differential function: fuel consumption calculation for diesel engines on board ships or locomotives.

  • Sum function: where flows are split-up in two pipelines and total flow has to be calculated.

  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres, and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs :

    • Flowmeter Inputs :
      • Pulse-type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
        Different pulse signal types are allowed for inputs A and B.

  • Signal Outputs :

    • Pulse outputs :
      • Function: Scaled pulse output according to the bi-directional accumulated total (e.g. a pulse every 3.25 gallons).
        Max. frequency: 500Hz.
        Adjustable pulse length from 0.001 sec. to 9.999 seconds. The directional switch output is switched as soon as the pulse output reflects a "negative" quantity.
      • Type: Two passive NPN transistors, active PNP transistors, or isolated electro-mechanical relays.

    • Alarm outputs: None

    • Analog outputs :
      • Function: Re-transmitting the differential or totalized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
      • Type: One passive isolated, floating, or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.

  • Supply :

    • Power Supply :
      • Long-life Lithium battery.
      • 4 – 20mA Output loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.

    • Sensor Supply: 3.2, 8.2, 12, 24V DC.

  • Hazardous Area :

    • Intrinsically Safe :

      • ATEX:
        Gas: II 1 G Ex ia IIB/IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T100 °C Da
      • IECEx:
        Gas: Ex ia IIC/IIB T4 Ga
        Dust: Ex ia IIIC T100 °C Da

    • Explosion Proof :
      • ATEX: 
        Gas: II 2 G / Ex d IIB T5 Gb
        Dust: II 2 D / Ex t IIIB T100°C Db

  • Communication

    • Function: All process data and settings can be read and modified through the communication link.

    • Protocol: Modbus ASCII / RTU.

    • Interface: RS232 / RS485 2-wire or 4-wire / TTL.

    • HART communication is available with the F018 & E018 Flow Rate Monitor / Totalizers.

Download Datasheet: Fluidwell F116 Differential or Sum Flow Computer

For further please contact us, marketing@wmablog.com

Another Article:

Berbagi:  

Komentar

Articles