Kem Kuppers' Inductive Pulse Amplifiers

 

VIE 02




Inductive pulse amplifiers of series VIE 02 for measuring cells in aluminum housing. We advise the identical carrier-frequency pulse amplifiers VTE 02 for measuring cells in steel housing.

The inductive pickups detect the r.p.m. of KEM flow meters. Each passing of a tooth will be detected contactless and produces a pulse at the output. Therefore each pulse corresponds to a fixed volume and the frequency corresponds to the volume flow. Versions with Push Pull output or NAMUR output (option: open collector output npn) are available.

The pickup is screwed into the meter via a thread M14×1.5 (option UNF ½”-20). Accordingly the VIE 02 fit on all KEM measuring cells.

Features

Application

The VIE 02 are inductive pickups for ZHA, SRA and HM nn-U in aluminium housing. They provide a wide frequency range and a relative low impact on pressure drop and low flow performance. For meters with stainless steel housing, nevertheless, the pickup series VTE 02 is recommended.

For applications in harzardous areas intrinsically safe versions with ATEX and IECEx certification for zone 1 and cCSAus certification for zone 0 and division 1 are available.

Specifications

Technical Data

  • Supply Voltage: UB: +5 up to 30 V DC, regulated, depending on version
  • Quiescent Current: IR < 1 mA
  • Frequence Range: 7 up to 5,000 Hz depending on flow meter
  • Ambient Temperature: -40 °C up to +80 °C [-40 °F up to +176 °F], depending on version
  • Medium Temperature: -40 °C up to +150 °C [-40 °F up to +302 °F]
  • Output Signal: Push-Pull, Open Collector (option) or NAMUR
  • Ex Protection:
    • ATEX: II 2G Ex ia IIC T4 Gb
    • IECEx: Ex ia IIC T4 Gb
    • cCSAus:
      • Class I, Div. 1, Groups A, B, C, D ; T4
      • Ex ia IIC T4 Ga
      • Class I, Zone 0 AEx ia IIC T4 Ga

IF and VIEG




cells in aluminum housing and applications with high temperature (-196 °C up to +350 °C [320.8 °F up to +662 °F]). For all other applications we recommend the carrier frequency transducers of the VTE series.

The inductive pulse amplifier detect the r.p.m. of KEM flow meters. Each passing of a tooth will be detected contactless and produces a pulse at the output. Therefore each pulse corresponds to a fixed volume and the frequency corresponds to the volume flow.

The pickup is screwed into the meter via a thread M14×1.5 (option UNF ½”-20). Accordingly the IF and VIEG fit on all KEM measuring cells.

  Another Article:

Features

Application

Contactless IF sensors detect the rotational speed of KEM flow meters. These are inductive sensors that output a sinusoidal voltage signal in the mV range. The remotely via cable connected VIEG amplifier unit amplifies and converts this signal. The spatial and thermal separation of the IF sensor and amplifier unit allows flows to be measured at extreme medium temperatures of -196 °C up to +350 °C [-320.8 °F up to +662 °F]

Specifications

Technical Data

  • Supply Voltage: UB: +7 up to 29 V DC
  • Quiescent Current: IR < 4 mA Frequence Range: 7 up to 3,000 Hz depending on flow meter
  • Ambient Temperature: -40 °C up to +80 °C [-40 °F up to +176 °F]
  • Medium Temperature: max. +350 °C [+662 °F] depending on IF sensor
  • Output Signal: frequency output (various modes)
  • Ex Protection: II 2G EEx ia IIC T4-T6

Download Datasheet: VIE 02 Kem Kuppers' Inductive Pulse Amplifiers

Download Datasheet: IF and VIEG Kem Kuppers' Inductive Pulse Amplifiers

Reference : kem-kueppers.com