The MS-716 is a special version of the SUPERtrol-1 Flow Computer which is supplied in a vehicle mount enclosure. The MS-716 satisfies the instrument requirements for a variety of flowmeter types in liquid applications. Multiple flow equations and instrument functions are available in a single unit with many advanced features. The alphanumeric display shows measured and calculated parameters in easy to understand format. Single key direct access to measurements and display scrolling is supported.
The versatility of the MS-716 permits a wide measure of versatility within the instrument package. The various hardware inputs and outputs can be “soft” assigned to meet a variety of common application needs. The user “soft selects” the usage of each input/output while configuring the instrument.
The isolated analog output can be chosen to follow volume flow, corrected volume flow, mass flow, temperature, or density using a menu selection. Most hardware features are assignable by this method. The user can assign the standard RS-232 Serial Port for data logging, transaction printing, or for connection
to a modem for a remote meter reading. A Service or Test mode is provided to assist the user during start-up system check out by monitoring inputs and exercising outputs and printing system setup.
Features
- Vehicle-Mount Enclosure; Rugged AluminumConstruction
- Class I, Div II Option Available
- Provisions for Sealing
- “EZ Setup” Guided Setup for First Time Users
- Rate/Total and Batching Functions
- Menu Selectable Hardware & Software Features
- Universal Viscosity Curve (UVC) and API Eq.
- Advanced Batching Features: Overrun Compensation, Auto batch Start, Print End of Batch, Slow Fill, 2 Stage Batching
- Isolated Outputs Standard
- RS-232 Port Standard, RS-485 Optional
Advanced Printing Capabilities
Windows™ Setup Software - On-Board Data Logging
- DDE Server & HMI Software Available
- Enhanced Modem Features for Remote Metering
- Quick Batching Sequence with Automatic Ticket
Printing
Another Article: |
Specifications
Flow Meters and Computations
Meter Types: All linear and square law meters supported
including Coriolis, vortex, turbine, magnetic, PD, target,
orifice, venturi, v-cone and many others
Linearization: Square root, 16 point table or UVC table
Computations: Volume, Corrected Volume & Mass
Fluid Computations: Temperature, Density, Viscosity and
API 2540 for petroleum.
Environmental
Indoor Use
Altitude up to 2000m
Operating Temperature: 0°C to +50°C (-20°C to 55°C optional)
Storage Temperature: -40°C to +85 C
Maximum Relative Humidity: 80% for temperatures up to 31°C decreasing linearly to 50% RH at 40°C
Mains supply voltage fluctuations not to exceed ±10%of the nominal voltage
Transient overvoltage according to INSTALLATION CATEGORY II (see UL 3101-1 Annex J)
POLLUTION DEGREE 2 by IEC 664 (see 3.7.3)
Materials: UL, CSA, VDE approved
UL Class 1 Division 2 (optional)
Listing
UL/ULC Listed (File No. E192404), CE Compliant
Display
Type: 2 lines of 20 characters
Types: Backlit LCD or OLED
Character Size: 0.2” nominal
User-programmable label descriptors and units of measure
Keypad
Keypad Type: Membrane Keypad with 16 keys
Keypad Rating: Sealed to NEMA 4X / IP65
Enclosure
Size: See Dimensions
Seal: NEMA4X
Materials: Aluminum
Real-Time Clock
The MS-716 is equipped with a battery-backed real-time clock with a display of time and date.
Format:
12 or 24 hour time display
Day, Month, Year date display
Power Input
The factory equipped power option is internally fused. An internal line to line filter capacitor and MOV are provided for added transient suppression.
110 VAC Power: 85 to 127 Vrms, 50/60 Hz
220 VAC Power: 170 to 276 Vrms, 50/60 Hz
DC Power:
12 VDC (10 to 14 VDC)
24 VDC (14 to 28 VDC)
Power Consumption:
AC: 11.0 VA (11W)
DC: 300 mA max.
Flow Inputs:
Analog Input:
Accuracy: 0.01% FS at 20° C
Ranges
Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC
Current: 4-20 mA, 0-20 mA
Basic Measurement Resolution:16 bit
Update Rate: 4 updates/sec
Automatic Fault detection: Signal over/under-range, Current Loop Broken
Calibration: Software Calibration (no trimmers) and Auto-zero Continuously
Extended calibration: Learns Zero and Full Scale of each range using special test mode.
Fault Protection: Reverse Polarity: No ill effects
Over-Voltage Limit: 50 VDC Overvoltage ;protection
Over-Current Protection: Internally current limited protected to 24VDC
Pulse Inputs:
Number of Flow Inputs: one with or without quadrature Input Impedance: 10 KΩ nominal
Pullup Resistance: 10 KΩ to 5 VDC (menu selectable)
Pull Down Resistance: 10 KΩ to common
Trigger Level: (menu selectable)
High-Level Input
Logic On: 3 to 30 VDC
Logic Off: 0 to 1 VDC
Low-Level Input (mag pickup)
Sensitivity: 10 mV or 100 mV
Minimum Count Speed: Menu selectable
Maximum Count Speed: Menu Selectable: 40Hz, 3000Hz or 20 kHz
Overvoltage Protection: 50 VDC
More Info Check Data Sheet: KEP meter ms716