PE 202 Seametrics Low-Flow Magmeter

PE 202 Seametrics Low-Flow Magmeter

PE 202 Flow Magmeter

The PE 202 Seametrics Low-Flow Magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in 3/4” to 1/4” pipe/tube. The housing is made of sturdy splashproof HDPE plastic.
 
With no moving parts, the PE202 can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 micro siemens) of varying viscosities and densities.
 
The PE meter is compact enough to fit most pump/injection systems. With zero straight pipes required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability.
 
The PE meter has an optoisolated current-sinking pulse output that can be connected to the Seametrics FT430/440 rate/total display or FT520 batch processor, as well as an optoisolated 4-20 mA current loop for powering analog devices. Outputs and power are provided through a 20 foot (6 meters) cable with an 8-pin female circular connector.
 
Feature
  • No moving parts
  • Requires no straight pipe
  • Pulse and/or 4-20 mA output
  • Chemical and corrosion-resistant
  • Insensitive to fluid density and fluid viscosity changes

Application

  • Chemical injection
  • Corrosive materials
  • Low flow applications
  • Pulsating flows (e.g., metering pump)

Specification

Pipe Size3/4”, 1/2”, 3/8”, 1/4”
Fittings1/2” NPT fittings standard in 3/4” or 3/8” flow body. NPT threaded adapters are available for the above pipe sizes.
MaterialsBodyPVDF
 ElectrodesPVDF carbon fiber filled
 GroundPVDF carbon fiber filled
 HousingHDPE with 25% glass
 Adapters (NPT)Polypropylene or PVDF
TemperatureAmbient0 ̊ to 130 ̊ F (-18 ̊ to 54 ̊ C)
 Fluid32 ̊ to 200 ̊ F (0 ̊ to 93 ̊ C)
Pressure150 psi
Flow Range-07520 GPM max. (0.2 GPM cutoff)
 -0383 GPM max. (0.03 GPM cutoff)
Accuracy-075±1% plus ±0.005 GPM of reading across a rated range
 -038±1% plus ±0.002 GPM of reading across a rated range
Output Signal
Optoisolated current sinking or current sourcing pulse output: 30 Vdc, 5 mA max
Optoisolated 4-20 mA current loop: 7 Vdc plus load voltage drop min; 50 Vdc max
 -075500 pulses/liter (1892 pulses/gallon)
 -0381000 pulses/liter (3785 pulses/gallon)
Power10–15 Vdc, 150 mA (linear power supply recommended)
Conductivity>20 micro siemens
Empty Pipe DetectionHardware/software, conductivity-based
EnvironmentalNEMA 4X standard; IP66 splashproof standard

Download Datasheet: Seametrics PE202

Berbagi:  

Komentar

Articles