Ryuki ODM-7000 Differential Pressure Flow Meter

 

The conventional ODM-7000 series has been supported by customers and has sold more than 100,000 units. This time, a new model has been added.

■ New product features :
(1) Up to 2 contacts can be installed.
(2) The position of the terminal box can be freely specified up, down, left, and right.
(3) Increased strength in consideration of material thickness.
④ Suitable for small to medium caliber lines.
(5) Combines the functions of the ODM7000 series.

● Measurement is possible even when the flow rate detection end and flow rate indicator are separated to a maximum horizontal distance of about 100m, and remote indication operation is possible.
● Since the main body is compact, it is easy to handle and can be easily installed in piping.
● The flow rate indicator has a mechanical structure, and the indication is extremely stable and reproducible.
● The indicator can be equipped with an electrical contact using a micro switch. It can send not only a flow rate instruction but also an alarm signal, and a maximum of two can be installed.
● Since the machine part of the indicator is in the atmosphere, it will not be corroded by fluid.
● Since the pressure-receiving part of the indicator uses a diaphragm, it is sufficient for general use in terms of strength and temperature.
● The flow range can be easily changed by replacing the restriction mechanism (orifice).
● Only the indicator can be replaced as an assembly.
● A straight pipe is required before and after the flow rate detector.

Model number :

  • ODM-7000S2DR type (2 contacts with stop valve)
  • ODM-7000SDR type (1 contact, with stop valve)
  • ODM-7000DR type (no contact, with stop valve)
  • ODM-7000S2ST type (2 contacts, without stop valve)
  • ODM-7000SST type (1 contact, no stop valve)
  • ODM-7000ST (no contact, no stop valve)

General specifications :

Measuring fluid

Liquid (water, industrial water, cooling water,
oils, other opaque liquids, etc.)

Port size

15A to 300A

Flow rate

15000L / min

Maximum working pressure

1.0MPa

Maximum operating temperature

100

Flow rate accuracy

Within ± 2% FS

Connection method

Flange type (JIS 5k JIS10k)

Body material

Brass (BS), PVC, SUS304, SUS316, etc.

Block material

Brass (BS), PVC, SUS304, SUS316, etc.

Orifice material

Brass (BS), PVC, SUS304, SUS316, etc.

Alarm contact

Up to 2 can be installed.

Flow direction

You can choose freely.

Block dimensions :

Caliber

JIS 5K

JIS 10K

15

48

52

20

52

58

25

62

70

32

72

80

40

78

85

50

88

100

65

112

120

80

125

130

100

145

155

125

180

185

150

210

215

200

255

265

250

320

325

300

365

370

* Please contact us for ANSI and JIS16K.

Measurement range (Please contact us for other products as well.)  :

Aperture (A)

H2O (L / min)

15

4 ~ 20
8 ~ 40

20

8-40
12-60

25

12-60
20-100

32

20-100
30-150

40

30-150
50-250

50

50-250
80-400

65

80-400
120-600

80

120-600
200-1000

100

200-1000
300-1500

125

300-1500
500-2500

150

500-2500
800-4000

200

800-4000
1200-6000

250

1200-6000
2000-10000

300

2000-10000
3000-15000

Reference: http://www.ryuki.jp

 

 

Berbagi:  

Komentar

Articles