The conventional ODM-7000 series has been supported by customers and has sold more than 100,000 units. This time, a new model has been added.
■ New product features :
(1) Up to 2 contacts can be installed.
(2) The position of the terminal box can be freely specified up, down, left, and right.
(3) Increased strength in consideration of material thickness.
④ Suitable for small to medium caliber lines.
(5) Combines the functions of the ODM7000 series.
● Measurement is possible even when the flow rate detection end and flow rate indicator are separated to a maximum horizontal distance of about 100m, and remote indication operation is possible.
● Since the main body is compact, it is easy to handle and can be easily installed in piping.
● The flow rate indicator has a mechanical structure, and the indication is extremely stable and reproducible.
● The indicator can be equipped with an electrical contact using a micro switch. It can send not only a flow rate instruction but also an alarm signal, and a maximum of two can be installed.
● Since the machine part of the indicator is in the atmosphere, it will not be corroded by fluid.
● Since the pressure-receiving part of the indicator uses a diaphragm, it is sufficient for general use in terms of strength and temperature.
● The flow range can be easily changed by replacing the restriction mechanism (orifice).
● Only the indicator can be replaced as an assembly.
● A straight pipe is required before and after the flow rate detector.
Model number :
- ODM-7000S2DR type (2 contacts with stop valve)
- ODM-7000SDR type (1 contact, with stop valve)
- ODM-7000DR type (no contact, with stop valve)
- ODM-7000S2ST type (2 contacts, without stop valve)
- ODM-7000SST type (1 contact, no stop valve)
- ODM-7000ST (no contact, no stop valve)
General specifications :
Measuring fluid |
Liquid (water, industrial water, cooling water, |
Port size |
15A to 300A |
Flow rate |
15000L / min |
Maximum working pressure |
1.0MPa |
Maximum operating temperature |
100 ℃ |
Flow rate accuracy |
Within ± 2% FS |
Connection method |
Flange type (JIS 5k JIS10k) |
Body material |
Brass (BS), PVC, SUS304, SUS316, etc. |
Block material |
Brass (BS), PVC, SUS304, SUS316, etc. |
Orifice material |
Brass (BS), PVC, SUS304, SUS316, etc. |
Alarm contact |
Up to 2 can be installed. |
Flow direction |
You can choose freely. |
Block dimensions :
Caliber |
JIS 5K |
JIS 10K |
15 |
48 |
52 |
20 |
52 |
58 |
25 |
62 |
70 |
32 |
72 |
80 |
40 |
78 |
85 |
50 |
88 |
100 |
65 |
112 |
120 |
80 |
125 |
130 |
100 |
145 |
155 |
125 |
180 |
185 |
150 |
210 |
215 |
200 |
255 |
265 |
250 |
320 |
325 |
300 |
365 |
370 |
* Please contact us for ANSI and JIS16K.
Measurement range (Please contact us for other products as well.) :
Aperture (A) |
H2O (L / min) |
15 |
4 ~ 20 8 ~ 40 |
20 |
8-40 12-60 |
25 |
12-60 20-100 |
32 |
20-100 30-150 |
40 |
30-150 50-250 |
50 |
50-250 80-400 |
65 |
80-400 120-600 |
80 |
120-600 200-1000 |
100 |
200-1000 300-1500 |
125 |
300-1500 500-2500 |
150 |
500-2500 800-4000 |
200 |
800-4000 1200-6000 |
250 |
1200-6000 2000-10000 |
300 |
2000-10000 3000-15000 |
Reference: http://www.ryuki.jp