The conventional ODM-7000 series has been supported by customers and has sold more than 100,000 units. This time, a new model has been added.
■ New product features
(1) Up to 2 contacts can be installed.
(2) The position of the terminal box can be freely specified up, down, left and right.
(3) Increased strength in consideration of material thickness.
④ Suitable for small to medium caliber lines.
(5) Combines the functions of the ODM7000 series.
● Measurement is possible even when the flow rate detection end and flow rate indicator are separated to a maximum horizontal distance of about 100m, and remote indication operation is possible.
● Since the main body is compact, it is easy to handle and can be easily installed in piping.
● The flow rate indicator has a mechanical structure, and the indication is extremely stable and reproducible.
● The indicator can be equipped with an electrical contact using a micro switch. It can send not only a flow rate instruction but also an alarm signal, and a maximum of two can be installed.
● Since the machine part of the indicator is in the atmosphere, it will not be corroded by fluid.
● Since the pressure receiving part of the indicator uses a diaphragm, it is sufficient for general use in terms of strength and temperature.
● The flow range can be easily changed by replacing the restriction mechanism (orifice).
● Only the indicator can be replaced as an assembly.
● A straight pipe is required before and after the flow rate detector.
Another Article: |
Model number
- ODM-7000S2DR type (2 contacts with stop valve)
- ODM-7000SDR type (1 contact, with stop valve)
- ODM-7000DR type (no contact, with stop valve)
- ODM-7000S2ST type (2 contacts, without stop valve)
- ODM-7000SST type (1 contact, no stop valve)
- ODM-7000ST (no contact, no stop valve)
General specifications
Measuring fluid | Liquid (water, industrial water, cooling water, oils, other opaque liquids, etc.) |
---|---|
Port size | 15A to 300A |
Flow rate | 15000L / min |
Maximum working pressure | 1.0MPa |
Maximum operating temperature | 100 ℃ |
Flow rate accuracy | Within ± 2% FS |
Connection method | Flange type (JIS 5k JIS10k) |
Body material | Brass (BS), PVC, SUS304, SUS316, etc. |
Block material | Brass (BS), PVC, SUS304, SUS316, etc. |
Orifice material | Brass (BS), PVC, SUS304, SUS316, etc. |
Alarm contact | Up to 2 can be installed. |
Flow direction | You can choose freely. |
Block dimensions
Caliber | JIS 5K | JIS 10K |
---|---|---|
15 | 48 | 52 |
20 | 52 | 58 |
25 | 62 | 70 |
32 | 72 | 80 |
40 | 78 | 85 |
50 | 88 | 100 |
65 | 112 | 120 |
80 | 125 | 130 |
100 | 145 | 155 |
125 | 180 | 185 |
150 | 210 | 215 |
200 | 255 | 265 |
250 | 320 | 325 |
300 | 365 | 370 |
* Please contact us for ANSI and JIS16K.
Measurement range
(Please contact us for other products as well.)
Aperture (A) | H2O (L / min) |
---|---|
15 | 4 ~ 20 8 ~ 40 |
20 | 8-40 12-60 |
25 | 12-60 20-100 |
32 | 20-100 30-150 |
40 | 30-150 50-250 |
50 | 50-250 80-400 |
65 | 80-400 120-600 |
80 | 120-600 200-1000 |
100 | 200-1000 300-1500 |
125 | 300-1500 500-2500 |
150 | 500-2500 800-4000 |
200 | 800-4000 1200-6000 |
250 | 1200-6000 2000-10000 |
300 | 2000-10000 3000-15000 |
Reference: http://www.ryuki.jp