The display shows the compensated flow rate, total, accumulated total, and actual line temperature. On-screen engineering units like Nm³ are easily configured from a comprehensive selection.
Advantages :
- Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / NEMA Type4X) .
It is so rugged, a truck can even stand on it! - Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications.
- Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost, and aggravation.
- Very diverse mounting possibilities: walls, pipes, panels, or directly onto outdoor sensors.
Features :
- Calculates compensated flow rate, total, and accumulated total based on a temperature/expansion relationship.
- Displays actual line temperature.
- Analog output signal reflecting the corrected flow rate.
- Displays total and flow rates simultaneously.
- Flow rate: seven 8mm (0.31") digits.
- Total - resettable: seven 17mm (0.67") digits.
- Accumulated total - not resettable: eleven 8mm (0.31") digits.
- Temperature: six 17mm (0.67") digits.
- Engineering units for flow rate, total, and temperature on the display.
- LED backlight.
- Intrinsically safe according to ATEX and IECEx.
- GRP, Aluminum, or high-grade stainless steel enclosure.
- Auto backup of settings and running totals in EEPROM memory.
- Ambient temperature: -40°C to +80°C (-40°F to 176°F).
- Various accessories are available for this product.
Applications :
- Applications where net flow calculation of liquids at normal conditions is desired without the influence of thermal product expansion.
- The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres, and temperatures between -40°C up to +80°C (-40°F up to 176°F).
Specification :
Product specifications :
- Signal Inputs :
- Flowmeter Inputs
Pulse type inputs:
Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Different pulse signal types are allowed for inputs A and B. - Temperature Inputs
- PT100 - 2 or 3-wire PRTD sensor.
- PT100 - 2 or 3-wire PRTD sensor.
- Flowmeter Inputs
- Signal Outputs:
- Pulse outputs
- Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons).
Max. frequency: 500Hz.
Adjustable pulse length from 0.001 sec. to 9.999 seconds. - Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
- Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons).
- Alarm outputs: None
- Analog outputs
- Function: Re-transmitting the compensated flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
- Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.
- Pulse outputs
- Supply :
- Power Supply
- Long-life Lithium battery.
- 4 – 20mA Output loop-powered.
- 8 – 24V AC/DC.
- 115 – 230V AC.
- Basic: 8 - 30V DC.
- Sensor Supply: 3.2, 8.2, 12, 24V DC.
- Power Supply
- Hazardous Area :
- Intrinsically Safe
- ATEX:
Gas: II 1 G Ex ia IIB/IIC T4 Ga
Dust: II 1 D Ex ia IIIC T100 °C Da - IECEx:
Gas: Ex ia IIC/IIB T4 Ga
Dust: Ex ia IIIC T100 °C Da
- ATEX:
- Explosion Proof
- ATEX:
Gas: II 2 G / Ex d IIB T5 Gb
Dust: II 2 D / Ex t IIIB T100°C Db
- ATEX:
- Intrinsically Safe
- Communication :
- Function: All process data and settings can be read and modified through the communication link.
- Protocol: Modbus RTU.
- Interface: RS232 / RS485 2-wire or 4-wire / TTL.
- HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.
- Function: All process data and settings can be read and modified through the communication link.