Rheonik RHM 02L Corioliss Mass Flow Sensor

Rheonik RHM 02L Corioliss Mass Flow Sensor is a meter designed for general-purpose flow measurement without the need for maintenance. Robust and accurate, the RHM20 outperforms other flow technologies at an attractively low cost of ownership.

Feature :

  • Pressure ratings up to 20000 psi / 1379 bar
  • Temperature ratings from -196 to 350°C(-320 to 662°F)
  • Mass flow uncertainty down to 0.10%
  • Density uncertainty down to 0.005 kg/liter
  • Repeatability better than 0.05%
  • Ranges between 2 g/min to 10 kg/min
  • Dual path (parallel) and single path (serial) internal pipe configurations are available
  • Omega Coriolis Design: unique torsion-driven oscillation system
  • Rheonik AnyPipeFitCommitment brings you the possibility to get any custom process connection type and size for savings on installation costs. Compact design with minimal footprint
  • Extremely compact design with minimal footprint
  • Approved for use in hazardous areas
  • Entire enclosure / external parts in stainless steel 316Ti available
  • Removable connection manifold version available for easy maintenance
  • Remote and integral transmitter versions are available

Application :

  • General Flow Control
  • High-Pressure Gas Dispensing
  • Additive Dosing
  • Mixing and Batching
  • Chemical Injection
  • Package and Container Filling
  • Polyurethane, Paint, Adhesives

Specification :

Nominal Flow (Qnom)*

2 kg/min

Minimum Flow (Qmin)*

0.050 kg/min

Serial Tube/ Single Path Versions

Flow rates Qnom and Qmin will be 50% of the above listed parallel/dual tube version of the same size

Operating Temperature

Fluid from -196°C to 350°C (-320°F to 662°F), see options in Part Number Code at Datasheet
Ambient from -50°C to 80°C (-58°F to 176°F), optional up to 210°C (410°F)

Pressure Ratings

Up to 1379 bar / 20000 psi - dependent upon material

Electrical Connection

Cable entry M25 x 1.5 (standard), M20 x 1.5, ½” NPT, ¾” NPT (optional)Max. cable length to remote RHE transmitter 100m / 330ft

Sensor Enclosure Materials

Stainless steel (standard), 316 stainless steel (optional)Coated aluminum terminal box (standard), 316 stainless steel terminal box (optional)

Enclosure Type

Protection class IP 66 / NEMA 4 (standard), NEMA 4X, IP68/69K (optional)

Wetted Materials

1.4435(316L) / 1.4539 (904L) / 1.4571 (316Ti) / 2.4602 (Alloy C22)
Sandvik HP160 (ideal for very high-pressure hydrogen), 1.4410 (SuperDuplex)
Standard seal types (manifold construction): FKM, FFKM, FVMQ Additional/customer-specific materials available upon request

Process Connections

Nearly any -the RHEONIK AnyPipeFitCommitment. Consult the factory for types/sizes not listed in this datasheet

Pressure Rating Compliance

Europe - PED according to Sound Engineering Practice (SEP)

Certifications and Approvals

Europe - PED according to Sound Engineering Practice (SEP)

Documentation, Testing, and Inspection

ATEX / IECExApprovals for zone 0 and 1 (suitably rated RHE required)
North American Approvals for Class I, Div. 1, Groups ABCD (suitably rated RHE required)
American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels

Project Documentation and QA Services

Rheonik offers of a full set of services for large and complex engineering projects. Typical services offered are, but not limited to:

Certificates of origin and conformity, mill certificates

Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance, etc.

Start-up and commissioning services on/offshore

Options

Enclosure heating for high-temperature applications
Mounting brackets: wall and floor mounting versions are available
Cleaning for oxygen service
Full-service painting to project specifications – consult the factory

* At Qnom, the pressure drop across a parallel tube sensor will be approximately 1- 3 bar (15-44psi) for H20. Sensors can be operated at higher flow rates but the pressure drop will be higher. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty will increase beyond 0.5% of the rate.

The flow specifications above relate to standard pressure, parallel tube, and manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops

Download Datasheet: Rheonik RHM 02L

For further please contact us, at sales@wmablg.com