Rheonik RHM 02L Corioliss Mass Flow Sensor is a meter designed for general-purpose flow measurement without the need for maintenance. Robust and accurate, the RHM20 outperforms other flow technologies at an attractively low cost of ownership.
Feature :
- Pressure ratings up to 20000 psi / 1379 bar
- Temperature ratings from -196 to 350°C(-320 to 662°F)
- Mass flow uncertainty down to 0.10%
- Density uncertainty down to 0.005 kg/liter
- Repeatability better than 0.05%
- Ranges between 2 g/min to 10 kg/min
- Dual path (parallel) and single path (serial) internal pipe configurations are available
- Omega Coriolis Design: unique torsion-driven oscillation system
- Rheonik AnyPipeFitCommitment brings you the possibility to get any custom process connection type and size for savings on installation costs. Compact design with minimal footprint
- Extremely compact design with minimal footprint
- Approved for use in hazardous areas
- Entire enclosure / external parts in stainless steel 316Ti available
- Removable connection manifold version available for easy maintenance
- Remote and integral transmitter versions are available
Application :
- General Flow Control
- High-Pressure Gas Dispensing
- Additive Dosing
- Mixing and Batching
- Chemical Injection
- Package and Container Filling
- Polyurethane, Paint, Adhesives
Specification :
Nominal Flow (Qnom)* |
2 kg/min |
Minimum Flow (Qmin)* |
0.050 kg/min |
Serial Tube/ Single Path Versions |
Flow rates Qnom and Qmin will be 50% of the above listed
parallel/dual tube version of the same size |
Operating Temperature |
Fluid from -196°C to 350°C (-320°F to 662°F), see options
in Part Number Code at Datasheet |
Pressure Ratings |
Up to 1379 bar / 20000 psi - dependent upon material |
Electrical Connection |
Cable entry M25 x 1.5 (standard), M20 x 1.5, ½” NPT, ¾”
NPT (optional)Max. cable length to remote RHE transmitter 100m / 330ft |
Sensor Enclosure Materials |
Stainless steel (standard), 316 stainless steel
(optional)Coated aluminum terminal box (standard), 316 stainless steel
terminal box (optional) |
Enclosure Type |
Protection class IP 66 / NEMA 4 (standard), NEMA 4X,
IP68/69K (optional) |
Wetted Materials |
1.4435(316L) / 1.4539 (904L) / 1.4571 (316Ti) / 2.4602
(Alloy C22) |
Process Connections |
Nearly any -the RHEONIK AnyPipeFitCommitment. Consult the factory for types/sizes not listed in this datasheet |
Pressure Rating Compliance |
Europe - PED according to Sound Engineering Practice (SEP) |
Certifications and Approvals |
Europe - PED according to Sound Engineering Practice (SEP) |
Documentation, Testing, and Inspection |
ATEX / IECExApprovals for zone 0 and 1 (suitably rated RHE
required) |
Project Documentation and QA Services |
Rheonik offers of a full set of services for large and
complex engineering projects. Typical services offered are, but not limited
to: Certificates of origin and conformity, mill certificates Data books including WPAR, WQS, NDT, test & quality
plans, functional testing, calibration procedures, customized packing,
factory acceptance, etc. Start-up and commissioning services on/offshore |
Options |
Enclosure heating for high-temperature applications |
* At Qnom, the pressure drop across a parallel tube sensor will be approximately 1- 3 bar (15-44psi) for H20. Sensors can be operated at higher flow rates but the pressure drop will be higher. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty will increase beyond 0.5% of the rate.
The flow specifications above relate to standard pressure, parallel tube, and manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops