The KPSI 720 is a submersible hydrostatic level transducer specifically designed to meet the rigorous environments encountered in liquid-level measurement and control. It can be configured to perform to specifications under the most adverse, reactive conditions. Every KPSI Transducer utilizes a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases. The assembly is integrated with supporting electronics in durable waterproof housing constructed of 316 stainless steel or titanium.
The attached electrical cable is custom manufactured and includes para-aramid synthetic fiber members to prevent errors due to cable elongation and a unique water block feature that self-seals in the event of accidental cuts to the cable. Each vented reference transducer is shipped with a Superdry Vent Filter that prevents moisture from entering the vent tube for one year without maintenance, even in the most humid environments.
Features :
- Custom polyurethane or ETFE cable lengths
- Welded 316SS or titanium body
- Custom level ranges up to 700 ft. (210 m) H2O
- Multiple analog outputs
- Multiple nosepiece styles
- Optional lifetime lightning protection
- Long-life vent filter or aneroid bellows
- Available molded cable seal
Applications "
- Lift stations
- Pump control
- Level control
- Surface water monitoring
- Landfill leachate
- Well Monitoring
- Groundwater monitoring
Specification :
Parameter |
Comment |
|
Level Ranges |
||
Full-scale level
ranges |
2.3 thru 700 ft. H20
(0.70 thru 210 m H20) |
Vented Gage
Reference |
Proof pressure |
1.5 x FS |
|
Burst pressure |
2.0 x FS |
|
Static Performance |
||
Static Accuracy |
±0.25% FSO |
BFSL method |
Resolution |
±0.0001% FS |
|
Electrical |
||
Excitation |
9-28V – VDC output |
0-5V, 0-2.5V, 0-4V |
Input current |
20 mA max |
For mA output |
Output |
4-20mA, 0-5 VDC,
0-2.5VDC, |
|
Zero Offset |
Rezero after
installation for optimum accuracy. Span is not affected (See
application note on website) |
|
Output Impedance |
See the loop
diagram for the mA output |
|
Insulation
Resistance |
100 mega-ohm at 50
VDC |
|
Circuit Protection |
Polarity,
surge/shorted output |
|
Physical |
||
Approximate Weight |
0.5 lbs. (227 g)
transducer |
|
Cable jacket
material |
Polyurethane
(standard) |
|
Cable pull strength |
200 lbs. (90 kg) |
|
Cable number of
conductors |
4 |
|
Cable conductor
size |
22 AWG |
|
Cable seal |
Molded polyurethane |
For polyurethane
cable |
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :