A wall mounted oxygen analyzer in a NEMA enclosure, suitable for indoor or outdoor. This single channel oxygen meter can be used with flow-through O2 cells for in-line gas analysis in safe as well as hazardous areas where ATEX approval is needed. The low detection limit of 0.05ppm offers ultra-low oxygen measurement down to a range of 0 to 10 ppm. Ideal for clean gas applications and when used with the XLT oxygen sensor type it allows measurement in pure carbon dioxide. The Analytical Industries long-life oxygen sensors are maintenance-free sealed electrochemical cells that don’t need top up of electrolyte and can be exchanged in few minutes.
Analytical Industries Trace Oxygen Analyzer | Sample Panel or Wall-mounted
Highlights
- Multiple user-configurable measurement ranges available
- General purpose or intrinsically safe (ATEX) models
- Fast recovery from exposure to air
- Can measure in pure CO2 with XLT sensor
- Two alarms with GPR-1500 A
GPR-1500 N (ATEX)
General-purpose or hazardous area trace oxygen analyzer with four measurement ranges from 0 to 10 ppm, up to 0-1%. The analyzer consists of a control unit with HMI and an easily accessible sensor housing all contained within a NEMA enclosure suitable for indoor or outdoor mounting. This unit is loop-powered (18-28 V DC) and provides a 4-20 mA output signal. All gas wetted parts are stainless steel, the XLT sensor can be supplied as an option.
GPR-1500 A
This unit is supplied with all of the above features, plus two user-configurable alarms and the ability to be mainspowered. For safe area use only.
Features
- Multiple user-configurable oxygen measurement ranges available
- General purpose or intrinsically safe (ATEX) models
- Fast recovery from exposure to air
- Can measure in pure CO2 with XLT sensor
- Two alarms with GPR-1500 A analyzer model
Applications
- Inert gas purity measurements
- Gas quality measurements in double glazing window manufacturing
- Blanket gas in small vessels
Specifications
GPR-1500 A | GPR-1500 N | GPR-1500 N ATEX | |
---|---|---|---|
Measurement range | 0-10, 0-100, 0-1000 ppm, 0-1%, (0-25%) | ||
Accuracy | < 2% of selected range at constant conditions | ||
Response time | T90 < 10 seconds | ||
Sensitivity (LDL) | 0.05 ppm | ||
Linearity | <1% of scale | ||
Sensor model | GPR-12-333 for inert gas streams | ||
Sensor life at 25ÂșC (77°F) and 1 atm | 24 months in < 1000 ppm O2 | ||
Calibration interval | 30 days | ||
Inlet pressure | 0.34-2 barg (5-30 psig) with atmospheric vent | ||
Flow rate | 0.5-1.0 l/m (1-2 SCFH) | ||
Gas connections | 1/8" or 1/4" compression tube fittings | ||
Wetted parts | Stainless steel | ||
Display | Graphical LCD 7 x 3.5cm (2.75 x 1.375"); resolution 0.01 | ||
Enclosure | Fiberglass NEMA 4X, 6.75 x 8.375 x 4.25" | Fiberglass NEMA 4X, 6.75 x 8.375 x 4.25" | |
Weight | 3.6kg (8lbs) | ||
Compensation | Temperature compensated output | Temperature | |
Signal output | 4-20 mA or 1-5 V, optional Modbus | 4-20 mA | |
Alarms | Two user configurable alarms | No alarms | |
Operating temperature | GPR sensor: 5°C to 45°C (41°F to 113°F) XLT sensor: -10° to 45°C (14°F to 113°F) | ||
Power | 12-28 V DC non-loop or 110-220 VAC | 18-24 V DC | |
Area classification | General purpose | UL: Class I, Division 1, Group C, D hazardous areas with external intrinsic safety barrier ATEX: II 2 G Ex ia IIB T4 Tamb -20°C to +50°C | |
Recovery time | 30 seconds in air to < 10 ppm in < 1 hour on N2 purge |
Reference : aii1.com
Download Datasheet : Analytical Industries Trace Oxygen Analyzer: Sample Panel or Wall-mounted
Another Article:
- Bamo Relative Humidity and Temperature HygroWiz
- M8 E2B, Omron Proximity Sensor
- Bamo Temperature Programmable 2 Wires Transmitter T2FR 5333
- E2NC Series, Omron-Smart Proximity Sensor
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :