Bamo Turbidity Monitor BAMOPHAR 436 | Descriptions

BAMOPHAR 436 is equipped with a color touch screen to set up the configuration and to display the turbidity, temperature and state of thresholds. Copies of measurement are available on 2 outputs 4-20 mA. BAMOPHAR 436 displays the turbidity value measured by one of our transmitters, to respond to process requirements.

  • TURBICUBE in PVC or PPH and TRUBOMAT GAB in stainless steel, are dedicated to in-line measurement
  • TURBISENS in PVC is an immersion probe with transmitter for measurements in tanks, basins, channels

A complete measuring system includes:

  • One monitor BAMOPHAR 436
  • One turbidity transmitter

OPTION: Extension terminal for a second parameter

  • Allows a second measurement (pH, Flow rate, Conductivity, etc.) (Configuration and display on the main unit)
  • Connected to main unit with 2 x 2-wire shielded cable (Cable length between both devices: max. 500 m)
  • RS422 and Data Logger of main unit are shared between both units
  • Wall or panel or DIN rail mounting: according to the model

Features

  • Color touch screen
  • Available scales: 0.001 to 9999 FNU, FAU, NTU, mg/l, g/l
  • 2 outputs 0/4-20mA (measurement & T.°C)
  • 3 Independent relays
  • 1 Relay for alarming function
  • OPTIONS: RS 422 /J-BUS + LOGGER Extension terminal for a 2nd measurement parameter

Application

Turbidity measurement for monitoring and processing water treatment:

  • Monitoring of source or wells for drinkable water
  • Monitoring of filtering diaphragms, ultra-pure water production units, reverse osmosis plants
  • Measurements in basins, decanting process
  • Monitoring of clogging and rinsing of filtering units
  • Monitoring of cooling towers
  • Control of wastewater before discharge

Specification

End-user interfaceColor touch screen 4.3'', resolution 480x272 pixels
 Display of measurements, menus, temperature, relay status
 Configuration - Keyword protected
Measuring scalesTo set up according the turbidity transmitter in use (from 0.001 to 9999 FNU, FAU, NTU, mg/l, g/l)
Sensor signal inputFor Turbidity transmitter 4-20 mA, 2-wire or 4-wire technique
Temperature displayInput signal for Pt 100 Ω 3-wire sensor, within the range 0 to 100 °C Or manually set up of operating temperature.
Relay outputs Configurable thresholds4 contacts N.O., potential free
Configurable thresholds2 Independent thresholds, for measurement or temperature
 1 Independent threshold, for measurement or temperature or to external function
 1 threshold for alarming function (Temperature sensor fault) or measurement out of range
Contact Initial resistance 100 mΩ max. (voltage drop 6 V DC 1 A)
Switching power831VAAC/3A/277VAC
 90W/3A/30VDC
Switching capacity (min.)100 mA, 5 V DC (variable according to switching frequency, environmental conditions and accuracy).
Measurement output0/4-20 mA (max. 600 Ω) proportional to measurement 0/4-20 mA (max. 600 Ω)
Temperature outputrange 0 to 100 °C
Main power 230 V - 50/60 Hz (others on request) - Consumption 10 VA
supply ModelsPanel mounting, 96x144 mm; Front IP65; Rear IP4, screw terminals
StorageWall mounting, IP65, cable glands -10 ... +70 °C
Operating temperature-5 ... +50 °C
InterfaceRS422 output, J-BUS link - Binary slave mode - 2400 to 9600 bauds
 Data Logger; Record of cycle average measurement - 150 000 records max. on memory

Ref: bamo.eu

Contact us : sales@wmablog.com or visit to our E-Commerce

Download Data Sheet: Turbidity Monitor BAMOPHAR 436