DH-X Dual Hall Effect Sensor AW Lake



AW Lake is a corporate from United States of America that sell some product such as Positive Displacement Meters, Turbine Flow Meters, Tricor Coriolis Flow Meter, Lake Variable Area Flow Meter, Lake Paddle Wheel Flow Meter "Flow Stat", Monitor&Controllers, Flow Sensor&Pickups. One of the product that comes from the categories of Flow Sensor& Pickups is DH-X Dual Hall Effect Sensor.

DH-X Dual Hall Effect Sensor

The DH Dual Hall Effect Pickups are microprocessor-based sensors for use with the JV-CG and JV-KG series of positive displacement flow meters. The DH sensors can detect both uni- and bi-directional flow. The sensors’ mode of operation is determined by an output selection switch located inside the housing. The DH detects the rotation of the flow meter’s gears and emits a frequency signal proportional to flow. The output signal is a square wave pulse which has a duty cycle of approximately 50%.

DH signal outputs are protected with a self-resetting fuse. This fuse has a 50mA nominal trip point. When a trip occurs, turn off power to the sensor and remove output load to reset fuse. The sensor has two different output configurations: sinking output and sourcing output.The DH sensor circuit board is equipped with a red and green LED. The red LED is a status LED which, when the sensor is operating properly, will flash once every 2 seconds. The green LED indicates the pulse of the input signal. Note that signals above 20Hz will look as solid green.

Features:

  • Meter Compatibility: Used with JV-CG and JV-KG up to -60 size (excluding JVM-01CG)
  • Flexible: Detects both uni- and bi-directional flow
  • Output Signal: Square wave pulse with duty cycle of approximately 50%
  • Protection: DH signal outputs protected with a 50mA nominal trip point self-resetting fuse
  • Two Output Configurations: Sinking output and sourcing output
  • Output Options: Choose from 2X pulse resolution in a signal pulse train (default) or a quadrature signal with a 90° phase shift

Another Article:

Specification:

  • Supply Voltage: +10 to 27 Volt DC
  • Supply Current: 18 mA @ 12 VDC, 25 mA @ 24 VDC
  • Duty Signal: 50% ± 15%
  • Minimum Signal: 0.5 Hz
  • Frequency Output: Flow dependent, up to 2,000 Hz
  • Driving Capacity: 50 mA Max resistive load
  • Output Impedance: ~ 40 Ohm - analog switch and self-resetting fuse
  • Temperature Range: -40° F to 185° F (-40° C to 85° C)

Download Data Sheet: DH-X Dual Hall Effect Sensor

Ref: aw-lake.com

Berbagi:  

Komentar

Articles