APG Hazardous Location Multi-Point Level Switch FLX

APG Hazardous Location Multi-Point Level Switch FLX

The Hazardous Location Multi-Point Level Switch FLX is designed specifically for point level detection of liquids in containers. Available in a wide variety of mounting types, the FLX is appropriate for use in classified flammable liquids. Each FLX is manufactured to the user’s specifications, making it fit to work precisely according to the application requirements. Stem mounted magnetic float switches. Every bit as customizable as the FL series, the FLX is the float switch for use in hazardous locations considered Class 1 Division 1 or 2 areas by CSA for North America. Place up to seven NO/NC switch points wherever needed along the stem customized  to your application. 7 custom configured NO/NC switch points for hazardous areas.

Class 1, Divisions 1 and 2

The FLX Series Level Switch is the float switch for use in hazardous locations considered Class I, Division 1 or 2 areas by CSA for North America.

Configuration Options

Pick the most effective switch point configuration for your needs. Choose between either Normally Closed or Normally Open for each switch point on the stem.

More Level Control

With up to 7 switch points, the FLX Series Level switch gives you more control. Place them wherever needed along the stem for a customized fit to your application.

Features

  • cCSAus hazardous area rating
  • Long switch life • Durable floats
  • Shock resistant construction
  • Up to seven switch points

Specification

Performance

 
Switch PointsUp to 7 NO/NC
 Custom Configuration

Connectivity

 
OutputsNO, NC

Physical

 
Mount & Stem Materials316L SS
Float Materials316L SS
Max Length153 in.

Electrical

 
Switch Rating50 VA, 180 VA
 Max Current
 0.5 A AC
Max VoltageCI, D1 - 24 VDC / 220 VAC
 CI, Z1 - 24 VDC
 CI, D2 - 220 VAC

Approvals

 
CertificationsCSA Class I, Div. 1, Groups C & D T3 (Ta 40°C)
 CSA Ex d, IIB T3; Class I, Zone 1, AEx d, IIB T3 (Ta 40°C)
 CSA Class I, Div. 2, Groups C & D T3 (Ta 85°C)

Environmental

 
Maximum Certification TemperatureClass I, Div. 1: 40° C
 Class I, Div. 2: 85° C

Download Data Sheet: Hazardous Location Multi-Point Level Switch FLX