These Proximity Sensors use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models. Proximity Sensors are available in models using high-frequency oscillation to detect ferrous and non-ferrous metal objects and in capacitive models to detect non-metal objects. Models are available with environment resistance, heat resistance, resistance to chemicals, and resistance to water.
Features and Benefits
- Standard Sensors for detecting ferrous
- A wide array of variations. Ideal for a variety of
- Models with different frequencies are also available to prevent mutual
- Superior environment resistance with standard cable made of oil-resistant PVC and sensing surface made of a material that resists cutting
- Useful to help prevent
- Cable protector provided as a standard feature
Ratings and Specifications
Size Shielded Item Model | M8 | M12 | M18 | M30 | ||||||
Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | Shielded | Unshielded | |||
E2E-X1R5Y@ | E2E-X2MY@ | E2E-X2Y@ | E2E-X5MY@ | E2E-X5Y@ | E2E-X10MY@ | E2E-X10Y@ | E2E-X18MY@ | |||
Sensing distance | 1.5 mm ±10% | 2 mm ±10% | 5 mm ±10% | 10 mm ±10% | 18 mm ±10% | |||||
Set distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | 0 to 14 mm | |||||
Differential travel | 10% max. of sensing distance | |||||||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.) | |||||||||
Standard sensing object | Iron, 8 ´ 8 ´ 1 mm | Iron, 12 ´ 12 ´ 1 mm | Iron, 15 ´ 15 ´ 1 mm | Iron, 18 ´ 18 ´ 1 mm | Iron, 30 ´ 30 ´ 1 mm | Iron, 54 ´ 54 ´ 1 mm | ||||
Response frequency | 25 Hz | |||||||||
Power supply voltage (operating voltage range)*1 |
24 to 240 VAC (20 to 264 VAC), 50/60 Hz | |||||||||
Leakage current | 1.7 mA max. | |||||||||
Control output | Load current *2 | 5 to 100 mA | 5 to 200 mA | 5 to 300 mA | ||||||
Residual voltage | Refer to Engineering Data on page 19. | |||||||||
Indicators | Operation indicator (red) | |||||||||
Operation mode (with sensing object approaching) |
Y1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 21 for details. Y2 Models: NC | |||||||||
Protection circuits | Surge suppressor | |||||||||
Ambient temperature range *1*2 | Operating/Storage: -25 to 70°C (with no icing or condensation) | Operating/Storage: -40 to 85°C (with no icing or condensation) | ||||||||
Ambient humidity range | Operating/storage: 35% to 95% (with no condensation) | |||||||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||||||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||||||||
Insulation resistance | 50 MÙ min. (at 500 VDC) between current-carrying parts and case | |||||||||
Dielectric strength | 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case | |||||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | ||||||||
Degree of protection | Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67 | |||||||||
Connection method | Pre-wired Models (Standard cable length: 2 m) and Connector Models | |||||||||
Weight (packed state) | Pre- wired Models Model |
Approx. 60 g |
Approx. 70 g |
Approx. 130 g |
Approx. 175 g | |||||
Connec- tor Models |
Approx. 15 g |
Approx. 25 g |
Approx. 40 g |
Approx. 90 g | ||||||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | |||||||
Sensing surface | PBT | |||||||||
Clamp- ing nuts | Nickel-plated brass | |||||||||
Toothed washer | Zinc-plated iron | |||||||||
Accessories | Instruction manual |
Download Catalog: Standard Proximity Sensor E2E
Ref: Omron.co.id
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :