These Proximity Sensors use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models. Proximity Sensors are available in models using high-frequency oscillation to detect ferrous and non-ferrous metal objects and in capacitive models to detect non-metal objects. Models are available with environment resistance, heat resistance, resistance to chemicals, and resistance to water.
Features
- Improved resistance to detergents and rusting
- Applicable to 120C (with DC 3-wire connection) (Heat resistance verified to 1,000 hours.)
- Resists typical detergents and disinfectants used in the food industry
- Water-resistant under high-temperature, high-pressure cleaning based on DIN 40050-9. (Pressure: 8,000 to 10,000 kPa, Water temperature: 80C, For 30 s at all angles
Specifications
Size Shielded Item Model | M12 | M18 | M30 | |
Shielded | ||||
E2EH-X3D@ | E2EH-X7D@ | E2EH-X12D@ | ||
Sensing distance | 3 mm | 7 mm | 12 mm | |
Set distance *1 | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 9.6 mm | |
Differential travel | 15% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on page 6.) | |||
Standard sensing object | Iron, 12 ´ 12 ´ 1 mm | Iron 21 ´ 21 ´ 1 mm | Iron 36 ´ 36 ´ 1 mm | |
Response frequency *2 | 500 Hz | 300 Hz | 100 Hz | |
Power supply voltage (operating voltage range) | 12 to 24 VDC, ripple (p-p): 10% max. (10 to 32 VDC, however, 24 VDC max. at temperatures over 100°C) | |||
Leakage current | 0.8 mA max. | |||
Control out- put | Load current | 3 to 100 mA (however, 3 to 50 mA at 100 to 110°C) | ||
Residual voltage *3 | Polarity Models: 3 V max. No polarity Models: E2EH-X@D@-T: (5 V max. *3 (Load current: 100 mA, Cable length 2 m) | |||
Indicators | D1 Models: Operation indicator (red), Setting indicator (yellow) D2 Models: Operation indicator (yellow) | |||
Operation mode (with sensing ob- ject approaching) | D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 7 for details. D2 Models: NC | |||
Protection circuits | Surge suppressor, Load short-circuit protection | |||
Ambient temperature range | Operating: 0 to 100°C (0 to 110°C 1,000 h) *4 Storage: -25 to 70° (with no icing or condensation) | |||
Ambient humidity range | 35% to 95% | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C. ±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C. -15% to +20% of sensing distance at 23°C in the temperature range of 100 to 110°C. | |||
Voltage influence | ±10% max. of sensing distance at rated voltage in the 15% rated voltage range. | |||
Insulation resistance | 50 MÙ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | |||
Shock resistance | Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions | |||
Degree of protection | IEC IP67, DIN 40050-9 IP69K *5 | |||
Connection method | Pre-wired Models (Standard cable length 2 m), Connector Models | |||
Weight (packed state) | Pre-wired Models | Approx. 80 g | Approx. 145 g | Approx. 220 g |
Connector Models | Approx. 30 g | Approx. 55 g | Approx. 125 g | |
Materials | Case, clamping nut | Stainless steel (SUS316L) | ||
Sensing surface | PBT | |||
Cable | Heat-resistant PVC cable (Pre-wired model) | |||
Accessories | Instruction manual |
*1. Use the yellow indicator on D1 Models as a guide.
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each E2EH-X@D@ DC 2-Wire Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 9.)
*4. Operation with power supplied for 1,000 h has been verified at 110°C. Do not bend the cable repeatedly at 100°C or higher.
*5. IP69K Degree of Protection Specification
IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050, Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane.