These Proximity Sensors use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models. Proximity Sensors are available in models using high-frequency oscillation to detect ferrous and non-ferrous metal objects and in capacitive models to detect non-metal objects. Models are available with environment resistance, heat resistance, resistance to chemicals, and resistance to water.

Features

  • Improved resistance to detergents and rusting
  • Applicable to 120C (with DC 3-wire connection) (Heat resistance verified to 1,000 hours.)
  • Resists typical detergents and disinfectants used in the food industry
  • Water-resistant under high-temperature, high-pressure cleaning based on DIN 40050-9. (Pressure: 8,000 to 10,000 kPa, Water temperature: 80C, For 30 s at all angles

Specifications

Size Shielded

Item                                             Model

M12M18M30
Shielded
E2EH-X3D@E2EH-X7D@E2EH-X12D@
Sensing distance3 mm7 mm12 mm
Set distance *10 to 2.4 mm0 to 5.6 mm0 to 9.6 mm
Differential travel15% max. of sensing distance
Detectable objectFerrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data (Reference Value) on page 6.)
Standard sensing objectIron, 12 ´ 12 ´ 1 mmIron 21 ´ 21 ´ 1 mmIron 36 ´ 36 ´ 1 mm
Response frequency *2500 Hz300 Hz100 Hz
Power supply voltage (operating voltage range)

12 to 24 VDC, ripple (p-p): 10% max.

(10 to 32 VDC, however, 24 VDC max. at temperatures over 100°C)

Leakage current0.8 mA max.
Control out- putLoad current3 to 100 mA (however, 3 to 50 mA at 100 to 110°C)
Residual voltage *3

Polarity Models: 3 V max.

No polarity Models: E2EH-X@D@-T: (5 V max. *3 (Load current: 100 mA, Cable length 2 m)

IndicatorsD1 Models: Operation indicator (red), Setting indicator (yellow) D2 Models: Operation indicator (yellow)
Operation mode (with sensing ob- ject approaching)D1 Models: NO       Refer to the timing charts under I/O Circuit Diagrams on page 7 for details. D2 Models: NC
Protection circuitsSurge suppressor, Load short-circuit protection
Ambient temperature rangeOperating: 0 to 100°C (0 to 110°C 1,000 h) *4 Storage:     -25 to 70° (with no icing or condensation)
Ambient humidity range35% to 95%

 

Temperature influence

±10% max. of sensing distance at 23°C in the temperature range of 0 to 70°C.

±15% max. of sensing distance at 23°C in the temperature range of 70 to 100°C.

-15% to +20% of sensing distance at 23°C in the temperature range of 100 to 110°C.

Voltage influence±10% max. of sensing distance at rated voltage in the 15% rated voltage range.
Insulation resistance50 MÙ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistanceDestruction: 1,000 m/s2, 10 times each in X, Y and Z directions
Degree of protectionIEC IP67, DIN 40050-9 IP69K *5
Connection methodPre-wired Models (Standard cable length 2 m), Connector Models
Weight (packed state)Pre-wired ModelsApprox. 80 gApprox. 145 gApprox. 220 g
Connector ModelsApprox. 30 gApprox. 55 gApprox. 125 g

 

Materials

Case, clamping nutStainless steel (SUS316L)
Sensing surfacePBT
CableHeat-resistant PVC cable (Pre-wired model)
AccessoriesInstruction manual

*1. Use the yellow indicator on D1 Models as a guide.

*2. The response frequency is an average value.

Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.

*3. The residual voltage of each E2EH-X@D@ DC 2-Wire Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 9.)

*4. Operation with power supplied for 1,000 h has been verified at 110°C. Do not bend the cable repeatedly at 100°C or higher.

*5. IP69K Degree of Protection Specification

IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050, Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a rate of 14 to 16 liters/min.

The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane.