AW Lake is a corporate from United States of America that sell some product such as Positive Displacement Meters, Turbine Flow Meters, Tricor Coriolis Flow Meter, Lake Variable Area Flow Meter, Lake Paddle Wheel Flow Meter "Flow Stat", Monitor&Controllers. One of the product that comes from the categories of Lake Variable Area Flow Meter is High Temperature Flow Meter.
High Temperature Flow Meter
Lake’s High Temperature Flow Meters enable flow monitoring of barrel heating fluids, thermal transfer fluids such as Syltherm® coolant flows, hydraulic circuits, and sub-circuits. Select from aluminum, brass, or stainless steel design for media compatibility requirements.
High temperature flow meters are available for air, water, and oil flow measurement with maximum temperature of 600°F. High Temperature Flow Meter enables flow monitoring of barrel heating fluids, thermal transfer fluids such as Syltherm® coolant flows, hydraulic circuits and sub-circuits.
Advantages:
- Choice of Materials: Select from aluminum, brass or stainless steel to meet system and media compatibility requirements.
- Unrestricted Mounting: Allows for horizontal, vertical or inverted installation and does not require straight plumbing on inlet or outlet.
- Multiple Ports Available: Standard selection of NPT, SAE and BSPP ports reduces the amount of adapters required for installation.
- Bi-Directional and Reverse Flow Option Offered: High temperature monitors are also available in bidirectional and reverse flow versions.
Features:
- Measuring Accuracy: ±2.0% of full scale
- Flow Measuring Range: 0.1-150 GPM (0.4-560 LPM)
- Maximum Operating Pressure: Liquids Aluminum and brass meters: 3500 PSIG (240 Bar) Stainless steel meters: 6000 PSIG (410 Bar) Air/Gas Aluminum and brass meters: 600 PSIG (40 Bar) Stainless steel meters: 1000 PSIG (69 Bar)
- Maximum Operating Temperature: H-Series 400°F (204°C) J-Series 600°F (315°C)
- Choice of Materials: Select from aluminum, brass or stainless steel to meet system and media compatibility requirements.
Another Article: |
Specification:
Measuring Accuracy: ±2.0% of full scale
Repeatability: ±1% of full scale
Flow Measuring Range: 0.1-150 GPM (0.4-560 LPM)
Maximum Operating Pressure:
- LiquidsAluminum and brass meters: 3500 PSIG (240 Bar)Stainless steel meters: 6000 PSIG (410 Bar)
- Air/GasAluminum and brass meters: 600 PSIG (40 Bar)Stainless steel meters: 1000 PSIG (69 Bar)
Maximum Operating Temperature:
- H-Series: 400°F (204°C)
- J-Series: 600°F (315°C)
Standard Calibration Fluids:
- Oil meters: DTE 25® @ 110°F (43°C), 0.873 sg
- Water meters: water @ 70°F (21°C), 1.0 sg
- Air meters: air @ 70°F (21°C), 1.0 sg & 100 PSIG (6.8 bar)
Filtration Requirement: 74 micron filter or 200 mesh screen minimum
Materials Of Construction:
- Window Tube: Pyrex®
- Window Seals: PTFE
- Casing & End Ports: Anodized Aluminum, Brass, or Stainless Steel
- Seals:
H-Series (400°F) : FKM w/ PTFE backup
J-Series (600°F): FFKM w/ PTFE backup - Transfer Magnet: PTFE coated Alnico
- All other internal parts: Stainless steel
Download Data Sheet: High Temperature Flow Meter
Ref: aw-lake.com
Komentar
Posting Komentar
Informasi Pilihan Identitas:
Google/Blogger : Khusus yang punya Account Blogger.
Lainnya : Jika tidak punya account blogger namun punya alamat Blog atau Website.
Anonim :