Hoffer Flow Control HP Insertion Series Turbine Flow Meter

Turbine flow meters liquids & gases, Insertion flowmeters

Hoffer Flow Control HP Insertion Series Turbine Flow Meter

The Hoffer HP Series of Insertion Turbine Flowmeters are designed for measuring liquid and gas flow in medium to large diameter pipes with accuracies inherent in the turbine flowmeter at a substantially lower price than in-line flowmeters.

Several versions are available including fixed, adjustable, bi-directional and high pressure. In addition a number of process fittings and materials of construction may be supplied to suit the demand of various applications.

HP Series Insertion Turbine Flowmeters for Liquids and Gas 4”-72” Pipe Diameters

Features

Features

  • Low cost.
  • Low pressure drop.
  • Wide flow turndown ranges for both liquids and gases.
  • Outstanding accuracy.
  • Applications from 4″ to 72″ pipe diameters. Specials upon request.
  • Process connection flexibility.
  • May be installed or removed from active line without stopping service.
  • -20 to +400°F standard operating temperature range with Viton Seal.

Applications

  • Precision flow measurement of liquid and gas applications in large diameter pipes at a lower cost than using an in-line flowmeter.

Insertion for Liquids:
Repeatable Flow Range: .25 to 50 FPS
Accuracy: ±1%

Insertion for Gas:
Repeatable Flow Range: 5 to 250 FPS
Accuracy: ±2%

Specifications

SPECIFICATIONS: LIQUIDS

Linear Flow Ranges:

(Examples)

Minimum Usable Flow Ranges:

5 to 50 FPS.

2 to 20 FPS.

1 to 10 FPS.

0.25 FPS with 2" Rotor.

0.5 FPS with 1½" Rotor.

LINEARITY: ±1% in 10:1 Flow Turndown Ratios.

Any turndown range with a minimum of 1 FPS and maximum of 50 FPS.

 

SPECIFICATIONS: LIQUIDS

Linear Flow Ranges:

(Examples)

Minimum Usable Flow Ranges:

5 to 50 FPS.

2 to 20 FPS.

1 to 10 FPS.

0.25 FPS with 2" Rotor.

0.5 FPS with 1½" Rotor.

LINEARITY: ±1% in 10:1 Flow Turndown Ratios.

Any turndown range with a minimum of 1 FPS and maximum of 50 FPS.

General Specifications

  • Repeatability : ±.25% Standard.
  • Max. Operating Pressure :
    150 PSI low pressure adjustable model.
    2500 PSI fixed model.**
    2500 PSI high pressure adjustable model.**
    ** (Dependent on process connection and temperature).
  • Bearing Types : Ceramic Hybrid Ball Bearings, Tungsten Cabide and Hard Carbon Composite Sleeve Bearings.
  • Materials : Stem, housing and rotor support are 316 stainless steel. Stem guide materials - brass (standard). Standard seal is Viton, with others available. Rotor - nickel 200, 430 stainless steel, 17.4 stainless steel (standard).
  • Output Signal (Magnetic Coil) :
    Output level - 10 mV RMS minimum.
    Wave shape - sinusoidal.
    DC resistance of sense coil - 2000 OHMS.
    Coil - variable reluctance type.

Download Datasheet : Hoffer Flow Control HP Insertion Series Turbine Flow Meter for Liquid and Gases

Reference : hofferflow.com

Berbagi:  

Komentar

Articles