Features
- Separate construction; full sealed stainless steel construction for submersible/inserted sensor; aluminum-alloy electric connection box; easy for installation, wiring, and calibration;
- MPM416WRK is full welded, stainless steel flexible tube armored;
- Explosion-proof version product conforms to Exia Ⅱ CT6 of Standard GB3836.4; Explosion-proof Certificate is issued
- Ship-use product conforms to CCS Rules of Classification of Sea-going Steel Ships(2006); Ship-use Product Certificate is issued;
- CE Certificat
Specifications
Pressure range | 1, 2, 5, 10, 20mH2O | ||||
Overpressure | 1.5times FS | ||||
Accuracy | +0.25%FS(typ.) +0.5%FS(max.) | ||||
Stability error | +0.1%FS(typ.) +0.2%FS(max.) pressure range>10mH2O | ||||
+10mmH2O(typ.) +20mmH2O(max.) pressure range≤10mH2O | |||||
Temp. drift | Zero drift,+ %FS/℃ | Sensitivitydrift,+%FS/℃ | |||
Range>10mH2O | 0.005(typ.) | 0.01(max.) | 0.02(max.) | ||
Range ≤10mH2O | 0.01(typ.) | 0.02(max.) | 0.02(max.) | ||
Range ≤5mH2O | 0.015(typ.) | 0.03(max.) | 0.02(max.) | ||
Range ≤2mH2O | 0.025(typ.) | 0.05(max.) | 0.02(max.) | ||
Transmitting | 2-wire | 3-wire | 3-wire | ||
Power supply | 15~28VDC(Intrinsic safe version is supplied through safe barrier) | ||||
Output signal | 4~20mADC | 0~10/20mADC | 0/1~5/10VDC | ||
Load(Ω) | <(U-15)/0.02A | <(U-15)/0.02A | >5k | ||
Material contacting with media | Housing: stainless steel 1Cr18Ni9Ti | O-ring: Viton | |||
Diaphragm: stainless steel 316L | Rubber casing: NBR | ||||
Cable: Φ7.2mm PVC/Polyurethane cable with vented tube | |||||
Operation temp. | -30℃ ~80℃ -10℃ ~60℃ | ||||
Storage temp. | -40℃ ~120℃ | ||||
Protection | IP68(sensor part), IP65(wiring part) | ||||
Ex-proof class | Exia Ⅱ CT6 |
Notes
- Please pay attention if the media is compatible with contacting material, especially pay attention to media density at measuring situation (except water);
- We provide the user with PVC or polyurethane cable; polyurethane cable is more flexible and wearable. If the user has no special requirements, the default would be PVC cable;
- If the product is installed in a lightning and thunder area, please note “lightning Protection” in the order; we suggest to use a lightning protection device to make sure power is grounding safely;
- When the MPM416WRK transmitter is working, please do not pull flexible steel tube to protect it;
- If the user has a special requirement, please feel free to contact our
Download Datasheet: MPM416WRK, Microsensorcorp-Submersible Level Transmitter