Pressure Sensors detect the pressure of liquids and gases, and Flow Sensors detect the flow rate of liquids. OMRON Sensing Components detect, measure, analyze, and process various changes that occur on productions sites, such as changes in position, length, height, displacement, and appearance. They also contribute to predicting and preventing future events.

Features and Benefits

  • Repeat accuracy of ±1% FS (setting resolution: 01 kPa), high-precision pressure control available.
  • Compact design (31 ´ 30 ´ 30 mm) saves mounting
  • Easy-to-read red LED
  • Analog current output models available (E8Y-A@Y).
  • Pressure port Rc (PT) 1/8 models available (-R).

Ratings

Model

 

Item

 

E8Y-AR2C

 

E8Y-AR5C

E8Y-A2C E8Y-A2C-RE8Y-A5B E8Y-A5C E8Y-A5C-R

 

E8Y-AR2Y

E8Y-A2Y E8Y-A2Y-RE8Y-A5Y E8Y-A5Y-R
Power supply voltage12 to 24 VDC ±10% with a ripple (p-p) of 10% max.
Current consumption50 mA max.75 mA max.
Pressure typeDifferential pressure
Rated pressure range0 to 200 Pa0 to 500 Pa0 to 2.00 kPa0 to 5.00 kPa0 to 200 Pa0 to 2.00 kPa0 to 5.00 kPa
Withstand pressure5 kPa50 kPa5 kPa5 kPa
Applicable fluidNon-corrosive gas and non-flammable gas

 

 

Linear output

Output current------------4 to 20 mA
Permissible load resistance-------------0 to 250 W
Precision------------±2.5%FS±1.0%FS
Linearity------------±2.5%FS±1.0%FS

 

 

 

Digital output

Output formNPN open collector (NO/NC) *
Load current100 mA
Output applied voltage30 VDC max.
Residual voltage1.0 V max. with a load current of 100 mA or 0.4 V max. with a load current of 16 mA
Repeat accuracy±2.5%FS±1.0%FS±2.5%FS±1.0%FS
Dis- playDisplay3-digit 7-segment red LED
Indicator lampOrange LED indicator (OUT1: lit when digital output is ON) Orange LED indicator (OUT2: lit when digital output is ON)
Response speed0.5 s max.
Display accuracy±1.0%FS
Setting resolution1 Pa0.01 kPa1 Pa0.01 kPa
Protection circuitsReverse polarity protection, load short-circuit protection
Ambient temperatureOperating: -10 to 55°C (with no icing)
Ambient humidityOperating: 25% to 85% (with no condensation)
Storage temperature-25 to 65°C
AccessoriesMounting Brackets (A and B), Instruction manual

Specifications

 

Temperature influence

E8Y-A2C/A5C: ±3%FS max. E8Y-AR5C: ±6%FS max. E8Y-AR2C: ±10%FS max.

 

Humidity influence

E8Y-A2C/A5C: ±3%FS max. E8Y-AR5C: ±6%FS max. E8Y-AR2C: ±10%FS max.
Degree of protectionIP40 (IEC)
Dielectric strength1,000 VAC at 50/60 Hz for 1 minute
Insulation resistance100 MW min. (at 500 VDC) between current-carrying parts and case
Vibration resistanceDestruction: 10 to 150 Hz, 0.75-mm single amplitude or 100 m/s2, 4 times each for 8 min in X, Y and Z directions
Shock resistanceDestruction: 300 m/s2 3 times each in X, Y and Z directions
Pressure port4.5-dia resin pipe or Rc (PT) 1/8 taper screw (-R type)
CableVinyl-insulated round cable 4 dia., Standard length: 2 m
WeightApprox. 80 g