Ranger Two™ LTRP-2 Ultrasonic Level Transmitter (up to 30ft)

Ranger Two™ LTRP-2 Ultrasonic Level Transmitter (up to 30ft) | Descriptions

The Ranger Two™ LTRP-2 Ultrasonic Level Transmitter is designed for level and distance measurement in remote monitoring and other difficult outdoor applications. The Ranger Two™ features surge protection which assures reliable performance in lightning prone areas. The Ranger Two™ is able to measure the distance of level with a range of 1ft. up to 30ft. Features include a stainless steel housing for rugged indoor or outdoor use, surge protection, and the ability to connect to one sensor up to 32 sensors optimized with RS-485 output to the CONNEX 3D Cellular Monitor. Serial data is addressable in MODBUS RTU protocol and options include ASCII. These all-weather sensors survive submersion and provide years of maintenance-free service.

Features and Benefits

  • Long-range, short dead band
  • Unaffected by optical factors like color and transparency
  • Surge protection
  • Low power consumption
  • Stainless 316 housing
  • Connect to one sensor, up to 32 sensors
  • Optimized with RS-485 output
  • Narrow beam with adjustable sensitivity
  • Temperature Compensated
  • No warmup mode, ready to measure with 1 sec.

Specification

Maximum Range30 feet (9.1 m) 

 

Resolution

Digital: 0.0034 inches (0.086 millimeters); Analog:4099 steps (0-10 VDC), 3279 steps (4-20 mA) 
Optimum Range20 ft. (6.1 m) 
Ready Time< 1 second after power application 
DeadbandTyp. < 10 in. (254 mm) 

 

Cable

2m standard length, potted into sensor body, PUR with shield and drain, other lengths available 
Beam Width7.5° 1° off axis @ -3db 
ConfigurationStored in sensor's non-volatile memory 

 

Conformance

CE, RoHS, Surge protection exceeds IEC 61000-4-5 
Data OutputModbus, ASCII streaming, specials 
Transducer75 kHz, Ruggedized Piezoelectric

 

Compatibility

Compatible with the CONNEX 3D™ Cellular Monitor 
ProtectionNEMA-4X, NEMA-6P, IP68 
Target Requirements 
AdjustmentSenixVIEW PC Software 

 

Objects

Detects liquid surface, flat or curved objects. Surface must reflect ultrasound to sensor 
Case Material316 Stainless Steel 
Temperature-40 to 158 F (-40 to 70 C) 

 

 

 

Distance Ranges (*)

Affected by size, shape, orientation of target (sound level reflected back to sensor), environment

Restrict use to Optimum Range when using over a wide range of environmental conditions

 
Humidity0 to 100% operating 
CompensationSelectable temperature Compensation 
Data Resolution0.0068 in. (0.172 mm) per count 

 

Repeatability

Repeatability Nominal 0.2% of range @ constant temp. Affected by target, distance, environment 

 

Orientation

Sensor should be oriented perpendicular to liquid surface for maximum reflection 

 

Update Rate

10 Hz (100 ms), Software adjustable; also affected by filter selections 

 

Optical

Unaffected by target color, light, transparency or other optical characteristics 

 

Modbus Protocol

Modbus RTU, 9600 to 115200 baud, 8 data bits, 1 stop, no parity 

 

Specifications are subject to change without notice.

 

 

ACSII Protocol

Five ASCII distance characters followed by Carriage Return; for single sensor connections only 

 

RS-485 Networks

From 1 to 32 sensors can operate in an addressable multi-drop network 

Ref: Flo-corp.com

Contact us : sales@wmablog.com

Download Datasheet: Ranger Two™ LTRP-2 Ultrasonic Level Transmitter (up to 30ft), Flocorp-Level Transmitter

Another Article: 

Hoffer Flow Control HO Series Turbine Flow Meter For Gases
Bamo Turbine Flow Meter BAMOTUR
LM GN Flow Meters Litre Meters Pelton Wheel Series
High Pressure Turbine Flow Meter HM Series AW Lake
MM Flow Meters Litre Meter Pelton Wheel Series

 