Bacharach PCA® 400 Active Sample Conditioner





Bacharach PCA® 400 active sample conditioner is used to enhance the performance of the PCA 400 Combustion and Emissions Analyzer in heavy industrial and commercial settings. The PCA 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary.

The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. The sample conditioner prevents water in the sample hose that could potentially absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2.

The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot.The dry, conditioned flue-gas sample is then passed through to the PCA 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

FEATURESBENEFITS
Keyed connection to PCA® probe and hoseQuickly creates a rugged, sturdy connection
Built-in temperature controllerMaintain cooler temperature above dewpoint
Built-in particulate filter with inspection windowUser can easily see when it’s time to change the filter
Built-in catch potEnsures a dry sample, every time
Direct temperature and draft signal passthrough to the PCA400Allows analyzer to perform all tests while the sample conditioner is connected
Self-contained designCompact, easy set-up and use

Specification

SpecificationDescription
Dimensions W x L x H3.2 in x 6.0 in x 6.0 in (81 mm x 152 mm x 152 mm)
Weight10 oz (284 g)
Control Temperature41° F nominal cooler temperature (5° C)
Catch Pot Capacity35 ml
Power SupplyAC/DC adapter, 100-264 VAC input, 15 V, 90 W DC output
Storage Temperature14° to 122° F (-10° to 50° C)
Storage Humidity10% - 90% RH, non-condensing
Operating Temperature41° to 104° F (5° to 40° C)
Operating Humidity10% to 90% RH, non-condensing

Ordering Information

P/NDescription
0024-8558North American sample conditioner kit. Includes sample conditioner, replacement filters (3 pk.) and NorthAmerican outlet power supply.
Accessories and Parts
0007-1658Inlet Filter, 30 Pieces
0024-1753Inlet Filter Cap (Requires 0105-5100)
0019-3345Catch Pot (Requires 0005-5127)
0024-1763Power Supply, 100-264 VAC, 15 VDC, 90 W
0024-1787Replacement O-ring Kit