The ECA 450 is an industrial-grade analyzer ideal for professionals concerned about combustion efficiency, environmental compliance, or both. Accommodating up to seven sensors, simultaneous measurements, and calculated parameters are evaluated to ensure that industrial equipment is meeting environmental regulations while burning safely and efficiently.
The ECA 450 is designed for on-demand or semi-continuous sampling of industrial furnaces, boilers, and other industrial combustion equipment. It complies with regulations such as U.S. EPA test methods, EN 50379, CTM-030, and state/local protocols including SCAQMD.
Note: The ECA 450 calculates CO2 value based on other measured values during the combustion process. It does not measure CO2 directly.
FEATURES : |
Measures up to 7 gases simultaneously |
Sensors are easily replaced or upgraded in the field |
Rugged suitcase design with a large, easy-to-read display |
Built-in printer for instant traceability and
record-keeping |
Specification :
Specification |
Description |
Power |
Internal rechargeable battery or via supplied wall adapter |
Run Time |
8 hours minimum |
Size (H x W x D) |
13.5 x 18.5 x 9 in. (34.3 x 47.0 x 22.9 cm) |
Weight |
25 lb. (11.3 kg) |
Fuels[1] |
Natural gas, coal, oil 2/4/5/6, wood, kerosene, bagasse,
propane, LPG, KOKS, LEG, biofuel |
Operating Conditions |
Analyzer: 32 to 104 °F (0 to 40 °C), 15 to 90% RH
|
Warm-up Time |
60 seconds |
Memory |
1000 locations |
Communications |
RS-232 |
Approvals |
CE mark |
[1] Depending upon combustion equation type – see manual for details
[2] For standard 12 in. probe, P/N 0024-3023
Measurement Ranges :
Measurement |
Description |
O2 |
0.1 to 20.9% |
CO (H2 Compensated) |
0 to 4,999 ppm |
CO (High Range) |
4,001 to 80,000 ppm |
NO |
0 to 3,500 ppm |
NO2 |
0 to 500 ppm |
SO2 |
0 to 4,000 ppm |
Combustibles |
0 to 5.00% (application dependent) |
Stack Temperature |
-4 to 2,400° F (-20 to 1,215° C) |
Primary / Ambient Temperature |
-4 to 999° F (-20 to 999° C) |
Pressure / Draft |
-27.7 to 27.7 inch |
Calculated Ranges :
Measurement |
Description |
Combustion Efficiency |
0.1 to 100% |
Excess Air |
1 to 250% |
CO2 |
0 to fuel-dependent maximum |
NOx (NO + NO2) |
0 to 4,000 ppm |
NOx (Referenced to %O2) |
0 to 17,000 ppm |
CO (Referenced to %O2) |
0 to 99,999 ppm |
NO (Referenced to %O2) |
0 to 14,900 ppm |
NO2 (Referenced to %O2) |
0 to 2,100 ppm |
SOx (Referenced to %O2) |
0 to 17,000 ppm |
Accuracy :
Measurement |
Description |
O2 |
±0.3% O2 on the practical concentration of flue gas |
Stack Temperature |
±4°F from 32 to 255° F (±2°C from 0 to 124° C) |
Primary / Ambient Air Temperature |
±2° F from 32 to 212° F (±1° C from 0 to 100° C) |
Pressure / Draft |
±2% of reading or ± 0.02 inch, whichever is greater |
CO |
±5% of reading or ±10 ppm, whichever is greater than 0 to
2,000 ppm |
NO |
±5% of reading or ±5 ppm, whichever is greater than 0 to
2,000 ppm |
NO2 |
±5% of reading or ±5 ppm, whichever is greater than 0 to
500 ppm |
SO2 |
±5% of reading or ±10 ppm, whichever is greater than 0 to
2,000 ppm |
HC |
±5% of a full scale |
Selectable Fuels |
Natural Gas, Oil #2, 4, 5, 6, Propane, Coal, Wood,
Kerosene, Bagasse |
Model :
N. Amer. P/N |
Description |
0024-7221 |
ECA 450
with O2 and CO sensors and probe with 12 in. sample tube |
0024-8400 |
ECA 450
with O2, CO, NOx kit (NO and NO2 sensors) |
0024-8401 |
ECA 450
with O2, CO, NOx & SOx kit (NO, NO2 and SO2 sensors)
|