Modulating valves LMV are used in combustion processes that require linear adjustment of air or gas flow. The flow varies proportionally to the opening angle of the inner mechanism, therefore flowrate is very predictable. The valves can be operated with stage control (3-point, MZ3 servomotor) or with continuous modulation (analog signals, MZ5 servomotor)
Function and Application
LMV works using a 2-cylinder mechanism, allowing a linear variation of the flow according to mechanism position, thanks to specifically shaped gas orifices. The outer cylinder is fixed while the inner cylinder can be rotated by the actuator, opening or closing the resulting gas passage. A flow adjustment is present and can be regulated acting on an external screw to set up easily the optimal working condition of the valve. Materials and mechanical tolerances are designed to assure low leakage, repeatability of the performance and reliability.
Another Article: |
Specification
Connections | Threaded f/f ISO 7-1 from Rp3/8 to Rp2½ |
Flanged ISO 7005 PN16 from DN40 to DN80 | |
Control Ratio | 25:1 |
Ambient Temperature | -15°C to +60°C (+5°F to +140°F) |
Max. Working Pressure | 500 mbar (50kPa) |
Flow Capacity | See Datasheet |
Leakage Rate | < 2% of maximum capacity |
Filtering Element | 600 µm |
Material in contact with the gas | Aluminum alloy Brass Stainless steel Plated steel Anaerobic adhesive Nitrile rubber (NBR) Fluoroelastomer (FPM) Acetal resin (POM) |
Voltage rate Servomotor MZ | 230 VAC 50/60 Hz 110 VAC 50/60 Hz 24 VAC/DC (depending on servomotor type) |
90° opening/closing time | 7,5 ... 120 sec (depending on servomotor type) |