The integral pickup detects the r.p.m. of the gears and the FOP provides a flow-proportional light pulse signal. The OPTV receiver will convert the light pulses into a current or voltage squarewave signal.
Features
The FOP is a fibre-optic amplifier for KEM gear flow meters used in highvoltage applications. Its integral pickup detects the r.p.m. of the gears and the FOP provides a low-proportional light pulse signal. The OPTV receiver will convert the light pulses into a current or voltage squarewave signal which maybe used for evaluation.
Applications
- Interference-free Pulse Detection
- No Electrical Connection to OPTV Receiver
- Anodised Aluminum Housing
- Light Weight and Handy Design
Specifications
Technical Data FOP 60
Power Supply | Lithium battery (exclusively use original batteries) |
Battery Lifetime | Max. 2 years with 24h-operation |
Ambient Temperature | -20 °C up to +50 °C [-4 °F up to +122 °F] |
Frequency Range | 7 up to 1,000 Hz |
Weight | Approx. 190 g |
Ingress Protection | IP65 |
Ex-protection, IS ATEX | II 2 G EEx ia IIC T4/T5/T6, BVS 03 ATEX E 156 CSA Ex ia IIC Class 1, Zone 0, AEx ia IIC |
Housing | Anodised aluminum (for dimensions please see drawings) |
Technical Data OPTV
Ambient Temperature | -20 °C up to +60 °C [-4 °F up to +140 °F] |
Supply Voltage | UB: 7 up to 30 V |
Quiescent Current | I R < 1,1 mA |
Output | Frequency output, constant pulsetime 500 μsec |
Electrical Data, Alternatively | Voltage outputs (3-wire connection) a. Active output High level: Uhigh > UB - 0.6 V - [2.5 kΩ × Iout (mA)] Low level: Ulow < 0.6 V + [1.3 kΩ × Iout (mA)] b. Passive output High level: Uhigh > U - [Iout (mA) × 1.3 kΩ] Low level: Ulow < 0.6 V + [1.3 kΩ × Iout (mA)] U is the voltage applied at the output, max. 30 V Current output (2-wire connection) a. For UB < 9 V (NAMUR supply units) High level: Ihigh > 2.2 mA b. For UB 7 up to 30 V High level: Ihigh = [(UB - 0.6 V)/1.3 kΩ] + Ilow |
Frequency Range | 3 up to 1,500 Hz according to flow meter |
Electrical Connection | Two off 4-pin screw terminals for supply and output signals (see wiring schemes) |
Ex Protection ATEX | II2 G EEx ia IIC T6, DMT 03 ATEX E 089X |
Housing | Grey-coloured polycarbonate for DIN hat top rail mounting |
Download Datasheet: FOP and OPTV Kem Kuppers Fibreoptical Amplifier and Lightpulse Receiver
Reference : kem-kueppers.com