Hoffer Flow Control HO Series Turbine Flow Meter For Gases

 

HOFFER FLOW CONTROLS was incorporated in 1969 in the state of New Jersey. For more than fifty years Hoffer Flow Controls has been designing and manufacturing quality turbine flowmeters and related process instrumentation. Our initial experience was in the field of cryogenic flow measurement. Today our reputation in this field is synonymous with quality.

The development of the modern turbine flowmeter can be traced back to David Potter, founder of Potter Aeronautical. Potter pioneered the development of the turbine flowmeter for the Navy in the 1940’s. The initial application for the Potter turbine flowmeter was in fuel flow measurement for Navy aircraft. Today fuel flow continues to be an ideal application for the turbine flowmeter.

Throughout the 1950’s and early 1960’s business at Potter Aeronautical of Union, New Jersey thrived. Potter held exclusive patents on the design of the turbine flowmeter. Potter Aeronautical began licensing the turbine flowmeter to other companies, both domestic and internationally. At the time Potter Aeronautical closed in 1968, its’ production manager was a young engineer named Ken Hoffer. Ken then founded his own turbine flowmeter company… Hoffer Flow Controls.

For the first ten years in business Hoffer Flow Controls specialized in cryogenic flow measurement systems. Hoffer pioneered the use of the turbine flowmeter in cryogenics.

During the late 1970’s we began to diversify into other markets, including oil patch, chemical and petrochemical, aerospace and energy measurement. More recently, we have introduced our products to the European Common Market, Central and South America and the Far East.

Today Hoffer Flow Controls manufactures high precision turbine flowmeters, not only for the cryogenic industry but is a world leader in turbine flowmeter technology for the measurement of clean liquids and gases throughout the processing industries.

 

Hoffer Flow Control HO Series Turbine Flow Meter For Gases

 

FOR GASES SIZES 1/4”-12”

Turbine flowmeters, Gas precision flow measurement

     Another Article:

Features

Features

  • Low cost.
  • Outstanding accuracy.
  • Linearity of +/-1% of reading typical.
    Linearity is density-dependent for a given meter. Consult factory for details.
  • Repeatability +/-.25%
  • Provides wide flow ranges.
  • Repeatable Flow Range: .15 to 12,000 ACFM.
  • Wide variety of process connections available.
  • Operate over a wide range of temperatures and pressures.
  • Exclusive use of hybrid ceramic ball bearings provide superior life.

Applications

  • Precision flow measurement of industrial gas applications within the process industries.

Specifications

  • Overrange : 150% of maximum flow (intermittently).
  • Available Turn Down Range : Dependent on gas density at user‘s operating conditions.
  • Linearity : ±1% of reading typical. ***
  • Repeatability : ±0.25% over tabulated repeatable range.
  • Available Temperature Range : -450°F to +300°F continuous (to +400°F intermittent heat). Dependent on bearing/coil selection.
  • End Fittings : MS flared and flanged styles are recommended. Other types available on request.
  • Bearing Styles : Self-lubricating, ceramic hybrid ball bearings.
  • Materials : 316/316L dual rated stainless steel standard. Consult with applications group for corrosive applications. Broad material list available.

Note: Performance enhancement techniques are routinely applied to produce wider linear and useable flow ranges. This technique is also used to improve linearity and repeatability. Consult the applications group at Hoffer with your requirements.

***Linearity is density-dependent for a given meter. Consult factory for details.***

Download Datasheet : Hoffer Flow Control HO Series Turbine Flow Meter For Gases