McCROMETER ExactSteam™ V-Cone® Flowmeter

 

McCROMETER ExactSteam™ V-Cone® Flowmeter


McCrometer’s ExactSteam V-Cone System is a complete flowmeter for steam metering, factory configured for energy metering or mass flow. The meter accurately measures steam across the entire range with technology-leading low flow cut off. In addition, V-Cone technology enables the lowest permanent pressure loss to maximize plant efficiency.

The ExactSteam V-Cone System’s innovative design delivers repeatable accuracy of ±0.5% of rate with up to a 50:1 flow range under the most difficult flow conditions. The ExactSteam V-Cone System acts as its own flow conditioner, fully conditioning and mixing the flow prior to measurement. Readings are always precise and reliable, even under changing flow situations.

McCROMETER ExactSteam™ V-Cone® Flowmeter | Descriptions

With this unique ability to self-condition flow, the ExactSteam V-Cone System virtually eliminates the need for upstream or downstream straight pipe runs. Thus, the ExactSteam V-Cone System can be installed nearly anywhere in a piping system or easily retrofit into an existing piping layout, resulting in significant installation flexibility and cost savings. In addition, the ExactSteam V-Cone System has proven to provide long-term performance with no moving parts to replace or maintain. It’s easy to reduce maintenance costs with the +25 year lifespan of the ExactSteam V-Cone System’s The meter accurately measures steam across the entire range with technology-leading low flow cut off. element.

V-Cone® is a registered trademark of McCrometer.

  • ISO Pressure Equipment Directive (PED)
  • NVLAP Accredited Calibration Laboratory: Lab Code 201023-0

     Another Article:

Key Features

  • A complete flowmeter for steam metering, factory configured for energy metering or mass flow
  • Accurately measure steam across the entire range with technology-leading low flow cut off
  • Makes retrofitting and new installations easier with minimum installation requirements – no flow conditioner required!
  • V-Cone technology enables the lowest permanent pressure loss to maximize plant efficiency
  • Reduce maintenance costs with the V-Cone flowmeter primary element’s 25+ year lifespan

Speficiations

  • Accuracy :± 0.5% for primary element, ±1% for total system
  • Body material: Stainless Steel or Carbon Steel
  • dP Transmitter
    Housing Material : F30 Aluminum
    Membrane Material : 316L
    Enclosure Rating : NEMA 4X/6P, IP66/67
    Electrical Connections : NPT1/2 thread
  • Fitting Type : Beveled or Raised Face 150# or 300# Flanges
  • Flow Computer: Output : 4-20 mA, Isolated Pulse
  • Installation Requirement : 0-3 diameters upstream, 0-1 diameters downstream
  • Line size : 2” to 24”
  • Manifold : Configuration: 3-Valve
  • Repeatability : ±0.1% or better
  • RTD :
    Sensor Type : PT-100, thin lm
    Range : -58° to 752° F (-50° to 400° C)
  • Turn down : Up to 50:1 with stacked configuration or 10:1 with compact

Reference : mccrometer.com